Installing Your Camera
• Baud Rate Settings
Select the transfer speed of a selected communication protocol.
No. | Baud Rate(BPS) | ||
1 | 2,400 | ON | ON |
2 | 4,800 | ON | OFF |
3 | 9,600 | OFF | OFF |
4 | 19,200 | OFF | ON |
• Communication Method Settings
Select a communication method for the camera.
| Function | ON | OFF |
SW2- #7 | Transfer Mode Switch |
• Communication Response Settings
Select a communication response method for the camera and controller: Response or No Response.
| Function | ON | OFF |
SW2- #8 | Response Mode Switch | Response | No Response |
• Termination Settings
To prevent the attenuation of communication signals between the camera and controller, 2 cameras in a longest distance for the camera and controller communication loop must be set up with the termination settings.
Camera Input Position | SW2- #10 | SW2- #11 |
Termination of Longest Path | ON | ON |
On the Path | OFF | OFF |
Installing Your Camera
• Camera Backup Settings
These settings are useful when the camera or its install base are damaged or malfunctions occur. When replacing the camera or its install base, you can transfer existing presets and sequence information to the replacement using these settings.
Backup Function | SW2- #9 | SW2- #12 |
Backup(IB→D) | OFF | OFF |
Backup(D→IB) | ON | OFF |
Backup Disable | - | ON |
-Backup(IB→D) : Enables transferring the current camera's sequence information to a new camera.
-Backup(D→IB) : Enables transferring the current camera's sequence information to a new install base.
*IB: Install base, D: Dome Camera
Notes
• To use a third party controller with this product, please contact our
• AD Protocol Control Method
-Input Camera OSD: 3+Auxiliary On
-Output Camera OSD: 3+Auxiliary Off
-Enter: IRIS Open
-ESC: IRIS Close
• For more information about the protocols, refer to our official website.
Camera ID DIP Switch Settings (SW1)
To set up camera IDs, refer to the “Camera ID Chart” next.