Bosch Appliances NDC-265-P Display Stamping, Time server IP address, Time server type

Page 41

IP Camera 200 Series

Advanced Mode en 41

 

 

5.Click one of the entries in the table to make changes. The entry is highlighted.

6.Click Delete to remove the entry from the table.

7.Choose other values from the list boxes under the table, to change the selected entry. Changes are immediate.

8.If there are empty lines at the bottom of the table, for example after deletions, add new data by marking the row and selecting values from the list boxes.

9.When finished, click OK to save and activate the table.

Note:

If a table is not created, there is no automatic switching. When editing the table, note that values occur in linked pairs (DST start and end dates).

Time server IP address

The camera can receive the time signal from a time server using various time server protocols and then use it to set the internal clock. The device polls the time signal automatically once every minute. Enter the IP address of a time server.

Time server type

Select the protocol that is supported by the selected time server. It is recommended to select the SNTP server protocol. This protocol provides high accuracy and is required for special applications and future function extensions. Select Time server if the server uses the RFC 868 protocol.

6.2.4Display Stamping

Various overlays or stamps in the video image provide important supplementary information. These overlays can be enabled individually and arranged on the image in a clear manner.

Camera name stamping

This field sets the position of the camera name overlay. It can be displayed at the Top, at the Bottom, or at a position of choice using the Custom option, or it can be set to Off for no overlay information.

Bosch Security Systems

Installation and Operation Manual

AR18-10-B012 v1.5 2011.01

Image 41
Contents IP Camera 200 Series Page Table of Contents Advanced Mode Basic ModeOperation via the browser Technical Data 105 Troubleshooting 101Maintenance 103 Safety precautions SafetyImportant safety instructions FCC & Ices Information FCC & Ices complianceBosch notices UL certificationDisclaimer More informationCopyrights En Safety IP Camera 200 Series Introduction FeaturesCD ROM UnpackingDisassembly InstallationMicroSDHC card MicroSDHC cardRJ45 Ethernet PoE Network and power connectorDC power connection Power connectionFunction Pin Socket I/O connectorAudio connectors Audio connectorsMounting the camera MountingCamera positioning Camera set-upIP Camera 200 Series Installation en Focal length and focus Closing the unit Resetting the cameraEn Installation IP Camera 200 Series Establishing the connection Browser connectionSystem requirements Protected network Password protection in cameraLivepage Connection establishedEn Browser connection IP Camera 200 Series Saving changes Basic ModeBasic Mode menu tree Password Device AccessPassword Camera nameDevice date, time and zone Confirm passwordDate/Time Network Click Set and RebootIP address Subnet maskAudio EncoderRecording System OverviewEn Basic Mode IP Camera 200 Series Advanced Mode menu tree Advanced ModeIdentification GeneralCamera ID Camera namePassword Date format Date/TimeDevice date / Device time Device time zoneTime server IP address Display StampingTime server type Camera name stampingAlarm message Alarm mode stampingTime stamping Display millisecondsAppearance Web InterfaceWebsite language Company logoLivepage Functions Logging Camera Picture SettingsDefault AR18-10-B012 v1.5 Profile name Profile ConfigurationTarget bit rate Maximum bit rateExpert Settings Video resolution4CIF/D1 720pDefault Encoder Streams Audio Camera LED Installer MenuMirror image Flip imageRecording Device manager Storage ManagementRecording media ISCSI MediaActivating and Configuring Storage Media Deactivating Storage Media Formatting Storage MediaRecording Profiles Stream profile settingsRecording includes Standard recordingAlarm recording Retention Time Holidays Recording SchedulerWeekdays Profile names Recording StatusActivate recording Recording statusAlarm Connections AlarmVideo transmission Select 10 in the Number of destination IP address list boxStream Remote portSSL encryption DecoderAuto-connect AudioVideo Content Analyses VCA Aggregation time s VCA configuration- ProfilesSensitivity Analysis typeMotion detector Debounce time 1 s Minimum object sizeSelecting the area Tamper detectionGlobal change slider Trigger delay sGlobal change Scene too brightReference check Scene too darkScene too noisy Appearing edges Deleting Holidays VCA configuration ScheduledIP Camera 200 Series Advanced Mode en Delay s VCA configuration Event triggeredTrigger Trigger activeAudio alarm Audio AlarmSignal Ranges NameAlarm E-Mail Test e-mail Destination addressSender name Relay Alarm inputInterfaces Trigger relay Relay followsRelay name Automatic IP assignment Network AccessDetails Video transmission DNS server addressHttp browser port Https browser portEnable DynDNS Interface mode ETHRCP+ port Telnet supportUser name Host nameForce registration now StatusAdvanced AuthenticationSnmp host address / 2. Snmp host address Snmp trapsRtsp port MulticastUPnP TCP metadata inputMulticast Address EnablePort StreamingFTP Posting Firmware ServiceMaintenance SSL certificate ConfigurationSystem Overview Maintenance logProcessor load Operation via the browserLivepage Image selection System Log / Event Log Digital I/ORecording video sequences Saving snapshotsRunning recording program Audio communicationIP Camera 200 Series Operation via the browser en Controlling playback RecordingsSelecting Recordings Export to FTPBookmarks Slide controlEn Operation via the browser IP Camera 200 Series LED indicators TroubleshootingResolving problems Customer serviceEn Troubleshooting IP Camera 200 Series Transfer and disposal MaintenanceRepairs En Maintenance IP Camera 200 Series Specifications Technical DataAccessories Page Bosch Security Systems