Bosch Appliances NDC-265-P operation manual Scene too dark, Scene too noisy, Reference check

Page 72

72 en Advanced Mode

IP Camera 200 Series

 

 

Scene too dark

Activate this function if tampering associated with covering the objective (for instance, by spraying paint on it) should trigger an alarm. The average brightness of the scene provides a basis for recognition.

Scene too noisy

Activate this function if tampering associated with EMC interference (noisy scene as the result of a strong interference signal in the vicinity of the video lines) should trigger an alarm.

Reference check

Save a reference image that can be continuously compared with the current video image. If the current video image in the marked areas differs from the reference image, an alarm is triggered. This detects tampering that would otherwise not be detected, for example, if the camera is turned.

1.Click Reference to save the currently visible video- image as a reference.

2.Click Select Area and select the areas in the reference image that are to be monitored.

3.Check the box Reference check to activate the on-going check. The stored reference image is displayed in black and white below the current video image, and the selected areas are marked in yellow.

4.Select the Disappearing edges or Appearing edges option to specify the reference check once again.

Disappearing edges

The area selected in the reference image should contain a prominent structure. If this structure is concealed or moved, the reference check triggers an alarm. If the selected area is too homogenous, so that concealing and moving the structure would not trigger an alarm, then an alarm is triggered immediately to indicate the inadequate reference image.

AR18-10-B012 v1.5 2011.01

Installation and Operation Manual

Bosch Security Systems

Image 72
Contents IP Camera 200 Series Page Table of Contents Basic Mode Advanced ModeOperation via the browser Troubleshooting 101 Maintenance 103Technical Data 105 Safety Safety precautionsImportant safety instructions FCC & Ices compliance FCC & Ices InformationUL certification Bosch noticesDisclaimer More informationCopyrights En Safety IP Camera 200 Series Features IntroductionUnpacking CD ROMInstallation DisassemblyMicroSDHC card MicroSDHC cardNetwork and power connector RJ45 Ethernet PoEPower connection DC power connectionI/O connector Function Pin SocketAudio connectors Audio connectorsMounting Mounting the cameraCamera set-up Camera positioningIP Camera 200 Series Installation en Focal length and focus Resetting the camera Closing the unitEn Installation IP Camera 200 Series Browser connection System requirementsEstablishing the connection Password protection in camera Protected networkConnection established LivepageEn Browser connection IP Camera 200 Series Basic Mode Basic Mode menu treeSaving changes Device Access PasswordPassword Camera nameConfirm password Date/TimeDevice date, time and zone Click Set and Reboot NetworkIP address Subnet maskEncoder AudioRecording System OverviewEn Basic Mode IP Camera 200 Series Advanced Mode Advanced Mode menu treeGeneral IdentificationCamera ID Camera namePassword Date/Time Date formatDevice date / Device time Device time zoneDisplay Stamping Time server IP addressTime server type Camera name stampingAlarm mode stamping Alarm messageTime stamping Display millisecondsWeb Interface AppearanceWebsite language Company logoLivepage Functions Logging Picture Settings CameraDefault AR18-10-B012 v1.5 Profile Configuration Profile nameTarget bit rate Maximum bit rateVideo resolution Expert Settings4CIF/D1 720pDefault Encoder Streams Audio Installer Menu Camera LEDMirror image Flip imageRecording Storage Management Device managerRecording media ISCSI MediaActivating and Configuring Storage Media Formatting Storage Media Deactivating Storage MediaStream profile settings Recording ProfilesRecording includes Standard recordingAlarm recording Retention Time Recording Scheduler WeekdaysHolidays Recording Status Profile namesActivate recording Recording statusAlarm Alarm ConnectionsSelect 10 in the Number of destination IP address list box Video transmissionStream Remote portDecoder SSL encryptionAuto-connect AudioVideo Content Analyses VCA VCA configuration- Profiles Aggregation time sAnalysis type Motion detectorSensitivity Minimum object size Debounce time 1 sSelecting the area Tamper detectionTrigger delay s Global change sliderGlobal change Scene too brightScene too dark Scene too noisyReference check Appearing edges VCA configuration Scheduled Deleting HolidaysIP Camera 200 Series Advanced Mode en VCA configuration Event triggered Delay sTrigger Trigger activeAudio Alarm Audio alarmSignal Ranges NameAlarm E-Mail Destination address Sender nameTest e-mail Alarm input InterfacesRelay Relay follows Relay nameTrigger relay Network Access Automatic IP assignmentDNS server address Details Video transmissionHttp browser port Https browser portInterface mode ETH Enable DynDNSRCP+ port Telnet supportHost name User nameForce registration now StatusAuthentication AdvancedSnmp host address / 2. Snmp host address Snmp trapsMulticast Rtsp portUPnP TCP metadata inputEnable Multicast AddressPort StreamingFTP Posting Service MaintenanceFirmware Configuration SSL certificateMaintenance log System OverviewOperation via the browser LivepageProcessor load Image selection Digital I/O System Log / Event LogSaving snapshots Recording video sequencesRunning recording program Audio communicationIP Camera 200 Series Operation via the browser en Recordings Controlling playbackSelecting Recordings Export to FTPSlide control BookmarksEn Operation via the browser IP Camera 200 Series Troubleshooting LED indicatorsResolving problems Customer serviceEn Troubleshooting IP Camera 200 Series Maintenance RepairsTransfer and disposal En Maintenance IP Camera 200 Series Technical Data SpecificationsAccessories Page Bosch Security Systems