Bosch Appliances NDC-265-P RCP+ port, Telnet support, Interface mode ETH, Network MSS Byte

Page 84

84 en Advanced Mode

IP Camera 200 Series

 

 

RCP+ port 1756

Activating RCP+ port 1756 allows unencrypted connections on this port. To allow only encrypted connections, set the Off option to deactivate the port.

Telnet support

Activating Telenet support allows unencrypted connections on this port. To allow only encrypted connections, set the Off option to deactivate telnet support, making telnet connections impossible.

Interface mode ETH

If necessary, select the Ethernet link type for interface ETH. Depending on the device connected, it may be necessary to select a special operation type.

Network MSS [Byte]

Set the maximum segment size for the IP packet's user data here. This gives the option to adjust the size of the data packets to the network environment and to optimize data transmission. Please comply with the MTU value of 1,514 bytes in UDP mode.

iSCSI MSS [Byte]

Specify a higher MSS value for a connection to the iSCSI system than for the other data traffic via the network. The potential value depends on the network structure. A higher value is only useful if the iSCSI system is located in the same subnet as the camera.

Enable DynDNS

DynDNS.org is a DNS hosting service that stores IP addresses in a database ready for use. It allows selecting the device via the Internet using a host name, without having to know the current IP address of the device. Enable this service here. To do this, obtain an account with DynDNS.org and register the required host name for the device on that site.

Note:

Information about the service, registration process and available host names can be found at DynDNS.org.

AR18-10-B012 v1.5 2011.01

Installation and Operation Manual

Bosch Security Systems

Image 84
Contents IP Camera 200 Series Page Table of Contents Basic Mode Advanced ModeOperation via the browser Troubleshooting 101 Maintenance 103Technical Data 105 Safety Safety precautionsImportant safety instructions FCC & Ices compliance FCC & Ices InformationUL certification Bosch noticesDisclaimer More informationCopyrights En Safety IP Camera 200 Series Features IntroductionUnpacking CD ROMInstallation DisassemblyMicroSDHC card MicroSDHC cardNetwork and power connector RJ45 Ethernet PoEPower connection DC power connectionI/O connector Function Pin SocketAudio connectors Audio connectorsMounting Mounting the cameraCamera set-up Camera positioningIP Camera 200 Series Installation en Focal length and focus Resetting the camera Closing the unitEn Installation IP Camera 200 Series Browser connection System requirementsEstablishing the connection Password protection in camera Protected networkConnection established LivepageEn Browser connection IP Camera 200 Series Basic Mode Basic Mode menu treeSaving changes Device Access PasswordPassword Camera nameConfirm password Date/TimeDevice date, time and zone Click Set and Reboot NetworkIP address Subnet maskEncoder AudioRecording System OverviewEn Basic Mode IP Camera 200 Series Advanced Mode Advanced Mode menu treeGeneral IdentificationCamera ID Camera namePassword Date/Time Date formatDevice date / Device time Device time zoneDisplay Stamping Time server IP addressTime server type Camera name stampingAlarm mode stamping Alarm messageTime stamping Display millisecondsWeb Interface AppearanceWebsite language Company logoLivepage Functions Logging Picture Settings CameraDefault AR18-10-B012 v1.5 Profile Configuration Profile nameTarget bit rate Maximum bit rateVideo resolution Expert Settings4CIF/D1 720pDefault Encoder Streams Audio Installer Menu Camera LEDMirror image Flip imageRecording Storage Management Device managerRecording media ISCSI MediaActivating and Configuring Storage Media Formatting Storage Media Deactivating Storage MediaStream profile settings Recording ProfilesRecording includes Standard recordingAlarm recording Retention Time Recording Scheduler WeekdaysHolidays Recording Status Profile namesActivate recording Recording statusAlarm Alarm ConnectionsSelect 10 in the Number of destination IP address list box Video transmissionStream Remote portDecoder SSL encryptionAuto-connect AudioVideo Content Analyses VCA VCA configuration- Profiles Aggregation time sAnalysis type Motion detectorSensitivity Minimum object size Debounce time 1 sSelecting the area Tamper detectionTrigger delay s Global change sliderGlobal change Scene too brightScene too dark Scene too noisyReference check Appearing edges VCA configuration Scheduled Deleting HolidaysIP Camera 200 Series Advanced Mode en VCA configuration Event triggered Delay sTrigger Trigger activeAudio Alarm Audio alarmSignal Ranges NameAlarm E-Mail Destination address Sender nameTest e-mail Alarm input InterfacesRelay Relay follows Relay nameTrigger relay Network Access Automatic IP assignmentDNS server address Details Video transmissionHttp browser port Https browser portInterface mode ETH Enable DynDNSRCP+ port Telnet supportHost name User nameForce registration now StatusAuthentication AdvancedSnmp host address / 2. Snmp host address Snmp trapsMulticast Rtsp portUPnP TCP metadata inputEnable Multicast AddressPort StreamingFTP Posting Service MaintenanceFirmware Configuration SSL certificateMaintenance log System OverviewOperation via the browser LivepageProcessor load Image selection Digital I/O System Log / Event LogSaving snapshots Recording video sequencesRunning recording program Audio communicationIP Camera 200 Series Operation via the browser en Recordings Controlling playbackSelecting Recordings Export to FTPSlide control BookmarksEn Operation via the browser IP Camera 200 Series Troubleshooting LED indicatorsResolving problems Customer serviceEn Troubleshooting IP Camera 200 Series Maintenance RepairsTransfer and disposal En Maintenance IP Camera 200 Series Technical Data SpecificationsAccessories Page Bosch Security Systems