Axis Communications P5534E user manual Reset to Factory Default Settings, Scripting, File Upload

Page 46

AXIS P5534–E PTZ Dome Network Camera

System Options

Parameter List - Shows the product's parameters and their current settings. This may prove useful when troubleshooting or when contacting Axis Support.

Connection List - Lists all clients that are currently accessing media streams.

Crash Report - Generates an archive with debugging information. The report takes several minutes to generate.

The log levels for the System Log and the Access Log are set under System Options > Support > Logs & Reports > Configuration . The Access Log can be configured to list all connections to the product (select Critical, Warnings & Info).

Advanced

Scripting

Scripting allows experienced users to customize and use their own scripts.

NOTICE

Improper use may cause unexpected behavior and loss of contact with the Axis product.

Axis strongly recommends that you do not use this function unless you understand the consequences. Axis Support does not provide assistance for problems with customized scripts.

To open the Script Editor, go to System Options > Advanced > Scripting. If a script causes problems, reset the product to its factory default settings, see page 46.

For more information, see www.axis.com/developer

File Upload

Files, for example webpages and images, can be uploaded to the Axis product and used as custom settings. To upload a file, go to System Options > Advanced > File Upload.

Uploaded files are accessed through http://<ip address>/local/<user>/<file name> where <user> is the selected user group (viewer, operator or administrator) for the uploaded file.

Plain Config

Plain Config is for advanced users with experience of Axis product configuration. Most parameters can be set and modified from this page.

To open Plain Config, go to System Options > Advanced > Plain Config . Axis Support does not provide assistance.

Reset to Factory Default Settings

Important

Reset to factory default should be used with caution. A reset to factory default will reset all settings, including the IP address, to the factory default values.

Note

The installation and management software tools are available on the CD supplied with the product and from the support pages on www.axis.com/techsup

To reset the product to the factory default settings:

1. Press and hold the control button and the restart button at the same time.

46

Image 46
Contents Axis P5534-E PTZ Dome Network Camera Liability About this documentLegal Considerations Intellectual Property RightsSupport Learn MoreTable of Contents Axis P5534-E PTZ Dome Network CameraFor technical specifications, see Connectors and ButtonsNetwork Connector Hardware OverviewSD Card Slot LED IndicatorsMidspan LED Indicators Control ButtonAccess from a Browser Access the ProductAccess from the Internet Live View Set the Root PasswordClick Create self-signed certificate Axis Media Control viewer toolbar Go to Setup EventsControls on the Live View Manual TriggerPTZ Controls Axis P5534-E PTZ Dome Network Camera Media Streams How to Stream H.264Axis Media Control AMC Alternative Methods of Accessing the Video Stream QuickTimeTM. The following paths can be usedAxis P5534-E PTZ Dome Network Camera Set Up the Product Basic SetupVideo Set Up Video StreamsClick Save to apply the new settings Pixel CounterStream Profiles 264Image Appearance Camera SettingsExposure Settings White BalanceOverlay Image SettingsDate/Time Formats in the online help To enable overlays Overlay ImageTo upload an overlay image Privacy MaskGo to Video Overlay Image Viewer Settings Configure the Live ViewDefault Viewer for Browsers Browser Viewer DescriptionUser Defined Links Go to Setup Live View ConfigOutput Buttons PTZ Pan Tilt Zoom Preset PositionsGatekeeper Advanced Guard TourOsdi Zones LimitsControls Operator Same as administrator but with lower priority Control QueueMotion Detection Set Up Motion Detection WindowsDetectors Motion Detection ParametersMedium level 50% Default valuesHigh level 100% Low level 0%Applications Install ApplicationGo to Setup Applications Application LicensesAxis P5534-E PTZ Dome Network Camera Convert Event Types to Action Rules Set Up Action RulesEvents Go to Events Action Rules and click AddTriggers ActionsCreate Schedules Add RecipientsRecipient Types Set Up Recurrences Go to Events Recurrences and click AddContinuous Recording RecordingsRecording List Go to Recordings ListSecurity To log in again and be configured to use this functionalitySystem Options UsersCertificates Date & TimeIeee CA CertificateBasic TCP/IP Settings NetworkLinux/Unix syntax Axis Internet Dynamic DNS ServiceAxis Internet Dynamic DNS Service requires IPv4 Linux/Unix exampleNTP Configuration Advanced TCP/IP SettingsDNS Configuration Host Name ConfigurationNAT traversal port mapping for IPv4 FTPSmtp email QoS Quality of ServiceUPnPTM can be disabled under System Options Network UPnPTM UPnPTMBonjour StorageRTP/H.264 SD CardFormat SD Card MaintenanceNetwork Share Go to System Options Storage Click Network ShareSystem Overview SupportSupport Overview Logs & ReportsScripting Reset to Factory Default SettingsPlain Config File UploadAxis P5534-E PTZ Dome Network Camera Emergency Recovery Procedure TroubleshootingUpgrade the Firmware Check the FirmwareProduct cannot be accessed from a browser Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product is accessible locally but not externallyVideo Camera Settings Problems with streaming H.264Video and image problems, general Key framesStorage and disk management problems Condensation in domeTechnical Specifications Memory Power Function/group Specifications System ApplicationMaintenance Installation aids ConnectorsFunction/group Specifications Video Performance ConsiderationsM2.4