Samsung SCC-C7439P user manual Communication, System Info, You can check the system information

Page 46

setup

COMMUNICATION

You can set the RS-485 communications setting in regard of the camera.

For selecting and saving each menu item, refer to “How to use the keyboard controller”. (page 20)

1.Select <MAIN MENU>-<COMMUNICATION>.

2.Select each item and set appropriately.

PRIORITY : Set the priority by selecting <HW> or <SW>.

When selected <HW>, the protocol, baud rate and address settings will follow those settings of the adaptor switch.

PROTOCOL, BAUD RATE, ADDRESS : When selected <SW>, you can manually set the protocol, baud rate and address.

COMMUNICATION

RS485

 

PRIORITY

HW

PROTOCOL

SAMSUNG

 

HALF

BAUD RATE

9600

ADDRESS

0

SYSTEM INFO

You can check the system information.

For selecting and saving each menu item, refer to “How to use the keyboard controller”. (page 20)

1.Select <MAIN MENU>-<SYSTEM INFO>.

2.The current system information is displayed.

SYSTEM INFO

TYPE

4_34PTZ_WDR_P

PROTOCOL

SAMSUNG

ADDRESS

0

COMM. TYPE

HW, RS485, HALF

BAUD RATE

9600

SERIAL NO.

000000000000000

CAMERA VER.

v1.00_000000

ALARM VER.

v1.00_000000

46_ setup

955G-EU1_SCC-C7439P-ENG-1.indd46 46

2009-10-15 8:56:2

Image 46
Contents Smart Dome Camera Overview English  Important safety instructions Contents Features What’s IncludedCamera At a GlanceFrame SET Installation & connection Optional Accessories for Installation955G-EU1SCC-C7439P-ENG-1.indd9 2009-10-15 Preparation PrecautionsHousing CableInstallation PIN Bush Power BNC Cable Bush 24V CableHousing Mount BushFrame SET 22P Connector Housing RackHousing Camera Screws Cover Dome Gasket Dome Hook Protective Camera Tape CoverCommunication Protocol Setup Initial SetupCamera Address Setup Samsung Half Samsung FullUse pins #5, #6 of SW603 to set the baud rate Baud Rate SetupSetting RS-422A/RS-485 Termination Factory default is 9600 BPSRS-422A/RS-485 Full Duplex Organization Same address in the networkMonitor Alarm Alarm OUT Connecting with Other deviceConnecting to a monitor CONTROLLER/DVR Power SourceTo connect Alarm OUT To connect AlarmTo connect the controller Power Supply Connecting the adaptor cableAdaptor Board Using OSD icons How to use the keyboard controllerCamera will resume the last run operation Main Menu Profile Burst DAY ModeNight EXT BurstCamera ID You can configure the general settings of the camera moduleCamera SET VPSIris BLC With Backlight set toMotion With this, you can adjust the AGC level of aAGC DNRFlickerless ShutterSENS-UP XDRDAY/NIGHT You can specify a recording mode according to the sceneAny excessively bright area in a night scene will be MASKed  You can specify Mask 1 and 2 simultaneously Auto Switch or Auto FocusWhite BAL SET-AUTO SET are not available955G-EU1SCC-C7439P-ENG-1.indd30 2009-10-15 Display P/T Zoom SpeedDisplay Zoom Digital ZoomReverse SyncAGC Color SUP POSI/NEGAIntelligent Video You can enable the motion detection and tracking functionsWhen multiple motions continue arbitrarily AdvancedPrivacy Zone ResolutionAlarm OUT DisplayPreset Select Position and adjust PAN Select the preset numberSET. pages 24 ~ Auto SET Auto Pan SetupSettings so define them again after the operation You can set the Auto PAN, PATTERN, and Auto Play955G-EU1SCC-C7439P-ENG-1.indd38 2009-10-15 Scan Setup Pattern SetupSelect the Start and move the camera using pan/tilt/zoom Auto Play Setup ~ 511 for PresetYou can set the north direction and the zone coverage Zone SETSelect Main MENU-ZONE SET Alarm SET Select Main MENU-ALARM SET Auto SET Sets the pattern and scan Clock SET Other SETOSD Color Factory DefaultsPassword Proportional P/TYou can check the system information CommunicationSystem Info Select Main MENU-SYSTEM InfoLanguage You can set the language of the user interfaceShortcut Keys Function KeyINT/LINE Lock SpecificationsSmart Dome Camera WDRPAN TiltProduct Appearance 955G-EU1SCC-C7439P-ENG-2.indd51 2009-10-15955G-EU1SCC-C7439P-ENG-2.indd52 2009-10-15