Tandberg Data 1080P VISCA/RS-232 control protocol, Network and interface commands, Push messages

Page 22

TANDBERG PrecisionHD 1080p/720p camera

Camera User Guide

Contentsontents

IntroductionIntroduction

PhysicalPhysicaliinterfacet rf

Cablesables

ConnectiConnect toto codec

Videoideo forformatsats

Daisyaisy chainingchaining

AppendicesApp dicesices

Contactontact usus

The VISCA™/RS–232 control protocol, cont...

Network and interface commands

Command set

Command packet

Comments

IF_Clear

8x

01 00 01 ff

Clear command buffer. Stop any

 

 

 

current operation in progress. Does not

 

 

 

do much on Rover.

Address_Set

8x

30 0p ff

p = address for this device. If x=8

 

 

 

(broadcast), increase p with 1 before

 

 

 

sending to chain.

Command_

8x

2p ff

p = Socket ID. Rover does not support

Cancel

 

 

multiple sockets. Commands will

 

 

 

always run to completion. Don’t use it

Push messages

Messages sent from camera to controller.

Command set

Command packet

Reply and comments

Network_

y0 38 ff

This indicates that cameras have been added

Change

 

to or removed from the chain.

 

 

It is recommended to wait 9 seconds after

 

 

receiving this message before doing a full

 

 

reconfigure.

IR_Push

y0 07 7d 02 gg hh ff

If IR mode is on, IR codes received by the

 

 

camera will be sent to the controller.

 

 

gg = IR ID

 

 

hh = keycode

D14640.01—MARCH 2010

22

www.tandberg.com

Image 22
Contents PrecisionHD Camera User Guide Table of Contents This guide?Tandberg PrecisionHD 1080p/720p camera Chapter Introduction12X/4X Disclaimers and Notices IntroductionPurpose of this document Products covered in this guidePhysical interface PrecisionHD 1080p 12X/4X camera PrecisionHD 720p camera HdmiAbout cables CableslessMaking your own cables Camera cablesHdmi cable HD-SDI cableConnecting the camera to the codec Using the camera with Profile having Codec C60 Using the camera with Profile having Codec C20How to connect the camera Using the camera with Codec C90 Codec C90 configurationsUsing the camera with Profile having Codec C90 Video output formats Tandberg PrecisionHD 1080p 12X/4X Line voltage frequencyDaisy chaining of the cameras Locate the Extra Camera and Power connectors Daisy chaining of the PrecisionHD 1080p 12X/4XDaisy chaining of the PrecisionHD 720p Appendices Tandberg PrecisionHD 1080p 12X/4X camera Controlling cameras using the Visca protocolRS-232 Commands and inquiries RS-232 ParametersVisca message format VISCA/RS-232 control protocol, Network and interface commandsPush messages Camera commands Command Command Packet CommentsPtzf movement commands Command Response Packet InquiriesDebug commands for Tandberg cameras Software upload commandsOther commands Video mode selection DIP SwitchTandberg PrecisionHD 720p camera Technical specificationsTandberg PrecisionHD 1080p 12X/4X cameras Tandberg PrecisionHD 1080pHeadquarters European Headquarters Tandberg