Command Summary

Command

 

Parameters

 

Subsystem Commands

ABOR

 

(none)

CAL

 

(See Appendix A in the Operating Manual)

[SOUR]:CURR[:LEV][:IMM][:AMPL]

 

<NRf+>[suffix]

[SOUR]:CURR[:LEV][:IMM][:AMPL]?

 

(none) MINMAX

[SOUR]:CURR[:LEV]:TRIG[:AMPL]

 

<NRf+>[suffix]

[SOUR]:CURR[:LEV]:TRIG[:AMPL]?

 

(none) MINMAX

[SOUR]:CURR:PROT:STAT

 

0 l ONOFF

(SOUR]:CURR:PROT:STAT?

 

(none)

[SOUR]:DIG:DATA[:VAL]

 

<NRf>

[SOUR]:DIG:DATA[:VAL]?

 

(none)

DISP[WIND]:MODE

 

NORMTEXT

DISP(WIND]:MODE?

 

(none)

DISP[:WIND][:STAT]

 

0 l OFFON

DISP[:WIND][:STAT]?

 

(none)

DISP[:WIND]:TEXT[:DATA]

 

<STR>

DISP[:WIND]:TEXT[:DATA]?

 

(none)

INIT[:IMM)

 

(none)

INIT:CONT

 

0 l OFFON

INIT:CONT?

 

(none)

Command Parameters

*CLS(None)

*ESE<NRf>

*ESE? (None)

*ESR? (None)

*IDN? (None)

*OPC (None)

Common Commands

Command Parameters

*OPC?

(None)

*PSC

<bool>

*PSC?

(None)

*RCL

<NRf>

*RST

(None)

*SAV

<NRf>

Command Parameters

*SRE<NRf>

*SRE? (None)

*STB? (None)

*TRG(None)

*TST? (None)

*WAI(None)

Programming Parameters

Table 7-1 list the programming parameters. For programming accuracy and resolution, refer to Appendix A.

Table 7-1. Power supply Programming Parameters (see note)

Parameter

CURR[:LEV] MAX and CURR[:LEV]:TRIG MAX

(Programming range is 0 to MAX) *RST Current Value

OUTP:PROT:DEL *RST Value

VOLT[:LEV] MAX and VOLT[:LEV]:TRIG MAX

(Programming range is 0 to MAX) *RST Voltage Value

VOLT:PROT MAX (Programming range is 0 to MAX) *RST OVP value

30.71 A

0.14 A

0 to 32.727 s (MAX)

200ms

81.9V

0V

96.0 V

MAX