Command Syntax | [SOURce]:VOLTage[:LEVel][:IMMediate][AMPLitude] <NRf+> | |||
| [SOURce][:VOLTage[:LEVel]:TRIGgered[:AMPLitude] <NRf+> | |||
Parameters | Table |
|
|
|
Default Suffix | V |
|
|
|
*RST Value | Table |
|
|
|
Examples | VOLT 200 MA | VOLTAGE:LEVEL 200 MA | ||
| VOLTAGE:LEVEL:IMMEDIATE:AMPLITUDE 2.5 | |||
| VOLT:TRIG 20 | VOLTAGE:LEVEL:TRIGGERED 20 | ||
Query Syntax | [SOURce]:VOLTage[:LEVel][:IMMediate][:AMPLitude]? | |||
| [SOURce]:VOLTage[:LEVel][:IMMediate][:AMPLitude]? | |||
MAX | [SOURce]:VOLTage[:LEVel][:IMMediate][:AMPLitude]? MIN | |||
| [SOURce]:VOLTage[LEVel]:TRIGgered[:AMPLitude]? | |||
| [SOURce]:VOLTage[LEVel]:TRIGgered[:AMPLitude]? MAX | |||
| [SOURce]:VOLTage[:LEVel]:TRIGgered[:AMPLitude]? MIN | |||
Returned Parameters | <NR3> VOLT? and VOLT:TRIG? return presently programmed | |||
| immediate and triggered levels. If not triggered level is programmed, | |||
| both returned values are the same. | |||
| VOLT? MAX and VOLT? MIN return the maximum and | |||
| minimum programmable immediate voltage levels. | |||
| VOLT:TRIG? MAX and VOLT:TRIG? MIN return the | |||
| maximum and minimum programmable triggered voltage levels. | |||
Related Commands | For VOLT | *SAV | *RCL | *RST |
| For VOLT:TRIG | ABOR | VOLT *RST |
VOLT:PROT
This command sets the overvoltage protection (OVP) level of the power supply. If the output voltage exceeds the OVP level, then the power supply output is disabled and the Questionable Condition status register OV bit is set (see "Chapter 8 - Status Reporting"). An overvoltage condition can be cleared with the OUTP:PROT:CLE command after the condition that caused the OVP trip is removed. The OVP always trips with zero delay and is unaffected by the OUTP:PROT:DEL command.
Command Syntax | [SOURce]:VOLTage:PROTection[:LEVel] <NRf+> | |
*Alternate Syntax | [SOURce]:VOLTage:PROTection:AMPLitude <NRf+> | |
Parameters | Table |
|
Default Suffix | V |
|
*RST Value | MAX |
|
Examples | VOLT:PROT 21.5 | VOLT:PROT:LEV MAX |
| VOLTAGE:PROTECTION:LEVEL | |
Query Syntax | [SOURce]:VOLTage:PROTection[:LEVel]? | |
| [SOURce]:VOLTage:PROTection [:LEVel]? MIN | |
| [SOURce]:VOLTage:PROTection [:LEVel]? MAX | |
Returned Parameters | <NR3> VOLT:PROT? returns presently programmed OVP level. | |
| VOLT:PROT? MAX and VOLT:PROT? MIN return the | |
| maximum and minimum programmable OVP levels. | |
Related Commands | OUTP:PROT:CLE | *RST *SAV *RCL |
* Available to accommodate earlier power supply programs.
84 Language Dictionary