PRECAUTIONS

Please read all safety and operating instructions before using this transceiver. For best results, be aware of all warnings on the transceiver and follow these operating instructions. Retain these safety and operating instructions for future reference.

1Power Source

Connect this transceiver only to the power source described in the operating instructions or as marked on the transceiver itself.

2Power Cable Protection

Route all power cables safely. Ensure the power cables can neither be walked upon nor pinched by items placed near or against the cables. Pay particular attention to locations near AC receptacles, AC outlet strips and points of entry to the transceiver.

3Electrical Shocks

Take care not to drop objects or spill liquids into the transceiver through enclosure openings. Metal objects, such as hairpins or needles, inserted into the transceiver may contact voltages resulting in serious electrical shocks. Never permit children to insert any objects into this transceiver.

4Grounding and Polarization

Do not attempt to defeat methods used for grounding and electrical polarization in the transceiver, particularly involving the input power cable.

5Outdoor Antenna Grounding

Adequately ground all outdoor antennas used with this transceiver using approved methods. Grounding helps protect against voltage surges caused by lightning. It also reduces the chance of a build-up of static charges.

EXAMPLE OF ANTENNA GROUNDING

 

ANTENNA

 

LEAD IN

GROUND

WIRE

CLAMP

ANTENNA

 

 

DISCHARGE UNIT

 

GROUNDING

 

CONDUCTORS

ELECTRIC SERVICE

GROUND CLAMPS

POWER SERVICE

EQUIPMENT

 

GROUNDING ELECTRODE

 

SYSTEM

6Power Lines

Minimum recommended distance for an outdoor antenna from power lines is one and one-half times the vertical height of the associated antenna support structure. This distance allows adequate clearance from the power lines if the support structure should fail for any reason.

7Ventilation

Locate the transceiver so as not to interfere with its ventilation. Do not place books or other equipment on the transceiver that may impede the free movement of air. Allow a minimum of 4 inches

(10￿cm) between the rear of the transceiver and the wall or operating desk shelf.

8Water and Moisture

Do not use the transceiver near water or sources of moisture. For example, avoid use near bathtubs, sinks, swimming pools, and in damp basements and attics.

9Abnormal Odors

The presence of an unusual odor or smoke is often a sign of trouble. Immediately turn the power OFF and remove the power cable. Contact a dealer or the nearest Service Center for advice.

10Heat

Locate the transceiver away from heat sources such as radiators, stoves, amplifiers or other devices that produce substantial amounts of heat.

11Cleaning

Do not use volatile solvents such as alcohol, paint thinner, gasoline or benzene to clean the cabinet. Use a clean cloth with warm water or a mild detergent.

12Periods of Inactivity

Disconnect the input power cable from the power source when the transceiver is not used for long periods of time.

13Servicing

Remove the transceiver’s enclosure only to do accessory installations described by this manual or accessory manuals. Follow provided instructions carefully to avoid electrical shocks. If unfamiliar with this type of work, seek assistance from an experienced individual, or have a professional technician do the task.

14Damage Requiring Service

Enlist the services of qualified personnel in the following cases:

a)The power supply or plug is damaged.

b)Objects have fallen or liquid has spilled into the transceiver.

c)The transceiver has been exposed to rain.

d)The transceiver is operating abnormally or performance has degraded seriously.

e)The transceiver has been dropped or the enclosure damaged.

iv

Image 6
Contents TS-570S Applicable Model Supplied AccessoriesAccessory Part Number Intelligent Digital Enhanced Communications SystemFeatures Writing Conventions FollowedKEY2 Contents Scan Memory FeaturesSpecifications Appendix COM Connector Protocol Index Operator ConveniencesPower Lines Power SourcePower Cable Protection CleaningInstallation Antenna ConnectionTransmission Line MHz 14 MHz 30 MHz Ground Connection DC Power Supply ConnectionInstallation Lightning ProtectionAccessory Connections Front PanelRear Panel Your First QSO DSP Slope High control Fully clockwise DSP Slope LOW controlYour Getting Acquainted Front PanelGetting Acquainted TF-SET button UP/DOWN buttonsSplit button Clear buttonMicrophone KEY and Paddle jacks Rear PanelGND post EXT SP jackDisplay @8USB @6M.SCR@7LSB #1FSKOperating Basics Switching Power ON/OFFAdjusting Volume Selecting VFO a or VFO BSelecting a Frequency Selecting a ModeAdjusting Squelch Front Panel MeterSelecting Transmit Power TransmittingMicrophone Gain Menu Access Menu SetupWhat is a MENU? Menu A/ Menu BFunction Selections Default Menu ConfigurationMenu Setup GroupSetting Transfer Rate bps Stop Bits SplitCross Reference for Menu Functions Basic Communicating SSB TransmissionAuto ZERO-BEAT CW TransmissionBasic Communicating TX SIDETONE/ RX Pitch FrequencyTX Deviation Selection FM TransmissionAM Transmission Press FilterTF-SET Transmit Frequency SET Specialized CommunicatingSPLIT-FREQUENCY Operation UP/DWNArrl 10-METER Band Plan FM Repeater OperationSpecialized Communicating Mode/ActivityFM Ctcss Operation Specialized Communicating Selecting Subtone FrequencyContinuous or Burst SUBTONES? Rtty Frequencies Digital OperationRtty Frequency Shift Keying Iaru Region A./CanadaPacket Frequencies Slow Scan TV/ Facsimile Satellite OperationSstv Frequencies Communicating Aids ReceivingSelecting Your Frequency AGC Automatic Gain Control RIT Receive Incremental TuningCommunicating Aids RX EqualizerVOX VOICE-OPERATED Transmit Delay TimePress Delay Microphone Input LevelXIT Transmit Incremental Tuning Communicating Aids Speech ProcessorChanging Frequency While Transmitting Monitoring Transmitted SignalsTransmit Inhibit Changing Transmit Bandwidth SSB/AMCW BREAK-IN Using Semi BREAK-IN or Full BREAK-INAuto Weighting Electronic KeyerCommunicating Aids Changing LOCKED-WEIGHT BUG KEY FunctionCW Message Memory Noise Blanker Rejecting InterferenceIf Filter Changing if Filter BandwidthDSP Tools AttenuatorPreamplifier Rejecting InterferenceNoise Reduction Beat CancelSetting NR2 Time Constant CW/ FSK ModesStoring Data in Memory Memory FeaturesConventional Memory Simplex ChannelsMemory Recall Memory FeaturesSplit-Frequency Channels Memory Recall and ScrollMemory-VFO Split Operation Memory ScrollTemporary Frequency Changes To use a memory channel for receivingMemory Features Memory Transfer Memory VFO TransferChannel Channel Transfer Erasing Memory Channels Memory Features Storing Frequency RangesFull Reset Confirming Start/End FrequenciesMemory Channel Lockout Quick MemoryStoring Into Quick Memory Press CLRMemory Features Recalling Quick Memory Temporary Frequency ChangesQuick Memory VFO Transfer Scan Hold ScanProgram Scan Scan Type PurposeALL-CHANNEL Scan Memory ScanScan Group ScanOperator Conveniences Microprocessor ResetSwitching ANT 1/ ANT Frequency Lock FunctionProgram Function Button Beep FunctionDisplay Dimmer Operator ConveniencesSetting UP Using Quick TransferQuick Data Transfer Computer Control Using a TransverterMenu Setting Transfer Rate Stop Bits Communication ParametersPresetting Automatic Antenna TunerAttune again Recording Messages Message PlaybackChecking Messages Changing Volume Sending MessagesChanging Inter-message Interval Voice New Mode AnnouncementMenu StepsPC-1A Optional AccessoriesDRU-3A PG-2ZInstalling Options Removing the Bottom CaseDRU-3A Digital Recording Unit Installing Options VS-3 Voice Synthesizer UnitFilters SO-2 TEMPERATURE-COMPENSATED Crystal Oscillator Tcxo Compatible Transceiver Connecting Peripheral EquipmentComputer Pin No. Pin NameLinear Amplifier Connecting Peripheral EquipmentRtty Equipment Antenna TunerMCP and TNC Pin No FunctionService Note MaintenanceService CleaningAccessing the Internal Fuse Internal AdjustmentsMaintenance Reference Frequency CalibrationFollowed TroubleshootingProblem Probable Cause Corrective Action DSP Slope LOW control orChanging Receive Press LSB/USB, CW/FSK, orPress LSB/USB or FM/AM to Repeater Operation TS-570S TS-570D SSB, CWFSK, FM Specifications SSB, CW, FSKAppendix Hardware DescriptionControl Operation COMError Messages Computer Control CommandsAlphabetical Commands ParametersAlphabetical Command Table OFF/ONParameter Table FormatMenu Selection Table for EX Command UP/DOWNComputer Control Command Tables I o !0DN UP DOWN/UP LK Frequency Lock MG MIC Gain RT RIT RX TX RX, TX VOX Function VFO Sstv