Camco 2.6, 4 manual Stereo Operation, Parallel-Mono Operation

Page 14

3.6.5 Stereo Operation

Two fully independent amplifier channels (normal operating mode).

WARNING!

RMS output voltages as high as 230 V are available at the output.

Wiring to the speaker loads must conform to NEC Class 3 safety standards.

3.0 INSTALLATION

MODE

PARALLEL

BRIDGEMONO

STEREO

VORTEX

3.6.7 Parallel-Mono Operation

Parallel operation of the two channels together.

MODE

PARALLEL

BRIDGEMONO

STEREO

3.6.6 Bridge-Mono Operation One-channel mono bridged operation.

MODE

PARALLEL

BRIDGEMONO

STEREO

VORTEX

The output terminals of the two channels are configured in parallel using an internal relay. The (single) load is connected either to the output of channel 1 or to that of channel 2 (as if in stereo). While the total output of the amplifier remains the same and the output voltage level is also the same as in stereo operation, the minimum impedance that can be connected is reduced by half due to the fact that current capability is doubled. Only Channel A-Input is active. This mode is useful when powering 3 speaker cabinets in parallel. A load

The second channel processes the same input signal, but with reversed phase. The (single) load is connected between the two positive channel outputs using a suitable connected SPEAKON connector. While the total output of the ampli- fier remains the same, both the available output voltage and the minimum impedance that can be connected are doubled, as compared with stereo oper- ation. Only Channel A-Input is active. A signal feeding Channel B will have no effect on the output.

balancing is achieved in this case.

NOTE: For parallel mono operation, to prevent damage of one SPEAKON connector and to reduce loss of power because of contact or cable resistance, it is highly recommended to wire speaker loads using both 2 channel SPEAKON connectors with all contacts connected.

P.14

CAMCO USER MANUAL

VORTEX POWER AMP SERIES

Image 14
Contents Page For Vortex Models 2.6, 4 Explanation of Symbols Please Refer ALL Servicing toSafety Servicing Replacement PartsSafety Check Manufacturers Address EC Declaration of ConformityManufacturers Name Declares that the product with the model nameContents Unpacking WelcomeWelcome to Camco Amplifier Facilities Vortex The RearPrecautions InstallationOn/off Switch MountingGround Lift Wiring Speakon ConnectionCooling 2 E.U.I. and XLR Connection Mode Indicators Mode SwitchBridge-Mono Operation One-channel mono bridged operation Stereo OperationParallel-Mono Operation Input Signal Chaining Operation Controls Volume ControlLimiter Switch Gain SelectorClip / Output Current Indicators Indicators 1 On / Failure IndicatorsSignal Indicators See 4.4.1,Clip Limiter and 4.4.3, Speaker Protect LimiterTo disable the Clip Limiter, see 4.2.3, Limiter Switch DC Servo Power Amp Over Current ProtectionPower Amp Thermal Protection Mains Protection Inrush Current LimitationFans Filter CleaningVortex Filter Assembly See .7, Input Signal Chaining Overview Or Remote Controls CAI CAI allows To Activate CAI Address Selection ProcedureCAI Status Indicator OptionsTroubleshooting On LED Flashing Sequences Examples of LED SequencesProblem No Channel Separation Problem No SoundProblem No Sound or Sound is too Low Problem Hiss Problem Distorted SoundProblem Music Sounds Frequency Filtered Problem Squeals and FeedbackSignal to Noise-Ratio SpecificationOutput Power Power Consumtion @ 230 Typical Max2Subject to technical alterations without prior notice Measurments Measurements of a typical performanceTHD+N @ 1 kHz, 4 Ohm load vs. input voltage Ch1, Ch2 Ohms Ch1, Ch2 Measurements of a typical performance Ch1, Ch2 Measurements of a typical performance1257 Vortex 2.6 Measurements of a typical performanceWarranty Information Owner’s Information Company Name Contact Expired WarrantyNature Of Problem Shipping AddressInternet Company InformationMailing Address