3.0 INSTALLATION

3.1 On/off Switch

NOTE: This switch does not isolate the appliance from mains.

It initiates start-up by activating the inrush current limiter. When the amp is connected to mains, only the line-filter and the input of the silicon controlled rectifier (fused) are energised.

10,5 mm

 

 

 

 

 

88,1 mm

76,2 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

465,0 mm

442,0 mm

411,0 mm

3.2 Precautions

When mounting or connecting the amp always disconnect it from mains.

3.3 Mounting

Use four screws and washers when mounting the amplifier to the front rack rails. Rear support is also recommended, especially in mobile and touring use.

mm

 

10,5

76,2 mm

 

436,0 mm 427,0 mm

P.11

CAMCO USER MANUAL

VORTEX POWER AMP SERIES

Image 11
Contents Page For Vortex Models 2.6, 4 Please Refer ALL Servicing to Explanation of SymbolsSafety Servicing Replacement PartsSafety Check Declares that the product with the model name EC Declaration of ConformityManufacturers Name Manufacturers AddressContents Unpacking Welcome Welcome to Camco Amplifier Vortex The Rear FacilitiesMounting InstallationOn/off Switch PrecautionsGround Lift Wiring Speakon ConnectionCooling Mode Switch 2 E.U.I. and XLR Connection Mode IndicatorsBridge-Mono Operation One-channel mono bridged operation Stereo OperationParallel-Mono Operation Input Signal Chaining Gain Selector Controls Volume ControlLimiter Switch OperationSee 4.4.1,Clip Limiter and 4.4.3, Speaker Protect Limiter Indicators 1 On / Failure IndicatorsSignal Indicators Clip / Output Current IndicatorsTo disable the Clip Limiter, see 4.2.3, Limiter Switch Mains Protection Inrush Current Limitation Power Amp Over Current ProtectionPower Amp Thermal Protection DC ServoFans Filter CleaningVortex Filter Assembly See .7, Input Signal Chaining Options To Activate CAI Address Selection ProcedureCAI Status Indicator Overview Or Remote Controls CAI CAI allowsOn LED Flashing Sequences Examples of LED Sequences TroubleshootingProblem No Channel Separation Problem No SoundProblem No Sound or Sound is too Low Problem Squeals and Feedback Problem Distorted SoundProblem Music Sounds Frequency Filtered Problem HissPower Consumtion @ 230 Typical Max2 SpecificationOutput Power Signal to Noise-RatioSubject to technical alterations without prior notice Measurements of a typical performance MeasurmentsTHD+N @ 1 kHz, 4 Ohm load vs. input voltage Ch1, Ch2 Ch1, Ch2 Measurements of a typical performance Ohms Ch1, Ch2 Measurements of a typical performanceVortex 2.6 Measurements of a typical performance 1257Warranty Information Shipping Address Expired WarrantyNature Of Problem Owner’s Information Company Name ContactInternet Company InformationMailing Address