Siemens CP 343-1 manual Extended Functions Compared with Version, Requirements General Operation

Page 7

english

Note

If there is a diagnostic connection to the CP via the CPU, configuration data cannot be downloaded automatically to the CP by the CPU at the same time!

Extended Functions Compared with Version 5

SReading and writing data in the FETCH/WRITE mode

The services FETCH and WRITE are supported for direct access to sy- stem memory areas on the SIMATIC S7 PLC via ISO transport and and ISO-on-TCP connections. The SIMATIC S7-300 with the CP 343-1 is always the server (passive connection establishment), while the fetch or write access (client functionality with active connection establishment) originates from a SIMATIC S5 PLC or other device

Requirements – General Operation

The following table shows the S7–300 CPUs with which the CP 343–1 can be operated with this range of functions:

Table 2

CPU

CPU 312 IFM

CPU 312 (T)

CPU 313

CPU 314

CPU 314 (T)

CPU 314 IFM

CPU 314 IFM (T)

CPU 315

CPU 315–2 DP

CPU 315–2 DP (T)

CPU 316–2 DP

CPU 318–2

MLFB–Number

6ES7 312–5AC02–0AB0

6ES7 312–5AC82–0AB0

6ES7 313–1AD03–0AB0

6ES7 314–1AE04–0AB0

6ES7 314–1AE84–0AB0

6ES7 314–5AE03–0AB0

6ES7 314–5AE83–0AB0

6ES7 315–1AF03–0AB0

6ES7 315–2AF03–0AB0

6ES7 315–2AF83–0AB0

6ES7 316–2AG00–0AB0

6ES7 318–2AJ00–0AB0

Product information CP 343–1

5

C79000–Z8964–C038–05

 

Image 7
Contents Stand/ Dated/ Edition/ Versione/ Versiòn 06/99 Produktinformation6GK7 343-1BA00-0XE0 Attenzione Contents Copyright E Siemens AG 1998..1999 All rights reserved Safety GuidelinesDesign ApplicationConfiguration CharacteristicsServices Requirements General Operation Extended Functions Compared with VersionRequirements ISO Transport Connections Reaction Times of ISO Transport Connections Characteristics of S7 CommunicationCharacteristics of ISO Transport Connections Performance DataCP Operating Mode Displays and Mode SelectorLED Displays Mode Selector Controlling the Operating ModeDownloading Firmware Further Information on OperationGroup status 8183 on the FC call interface Module Accessories InstallationSteps in Installation ProcedurePG/PC Connection Attaching the CP 343-1 to Industrial Ethernet Optical Switch Modul OSM General Technical Data Technical DataPinout Connector for Industrial EthernetArea of Application Installation GuidelinesProduct name EU Directive EMC89/336/EECOrder Numbers Contains detailed informationDear customer 90713 Fürth
Related manuals