Siemens CP 343-1 manual Pinout, Connector for Industrial Ethernet

Page 18

english

3.2Pinout

Connector for Industrial Ethernet

On the front panel of the CP 343-1, there is a 15-pin sub D female connector with a sliding locking mechanism for connecting a transceiver cable. The signals of an ITP interface can also be applied to this connector (switchover by relay).

For operation via the AUI interface, use the 727-1 transceiver cable. A special SIMATIC NET ITP cable must be used when operating via the ITP interface.

CP 343–1

SF

RUN

STOP

RUN

STOP

R

Figure 6 Connector Pinout Diagram

Pin– No

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Signal– name

MEXT

CLSN

TRMT / TPETXD

Ground

RCV / TPERXD

M 15 V

TPE_SEL

Ground

CLSN_N

TRMT_N /

TPETXD_N

Ground

RCV_N /

TPERXD_N

P15 V

Ground

Function

External ground, shield

Collision +

Transmit + / TPE transmit data +

Ground 5V

Receive + / TPE Receive data +

Ground 15 V

AUI/ITP switchover

Ground 5 V

Collision –

Transmit – / TPE Transmit data –

Ground 5V

Receive – / TPE Receive data –

+15 V

Ground 5V

Notes on the Pinout

The pinout complies with the IEEE 802.3 AUI interface.The signals TPETXD / TPETXD_N and TPERXD / TPERXD_N implement the ITP interface.

16Product information CP 343–1

C79000–Z8964–C038–05

Image 18
Contents Produktinformation Stand/ Dated/ Edition/ Versione/ Versiòn 06/996GK7 343-1BA00-0XE0 Attenzione Contents Safety Guidelines Copyright E Siemens AG 1998..1999 All rights reservedApplication DesignCharacteristics ConfigurationServices Extended Functions Compared with Version Requirements General OperationRequirements ISO Transport Connections Performance Data Characteristics of S7 CommunicationCharacteristics of ISO Transport Connections Reaction Times of ISO Transport ConnectionsDisplays and Mode Selector CP Operating ModeLED Displays Controlling the Operating Mode Mode SelectorFurther Information on Operation Downloading FirmwareGroup status 8183 on the FC call interface Installation Module AccessoriesProcedure Steps in InstallationPG/PC Connection Attaching the CP 343-1 to Industrial Ethernet Optical Switch Modul OSM Technical Data General Technical DataConnector for Industrial Ethernet PinoutEU Directive EMC89/336/EEC Installation GuidelinesProduct name Area of ApplicationContains detailed information Order Numbers90713 Fürth Dear customer