english
3 Technical Data
3.1General Technical Data
Dimensions and Weight
Dimensions, module in casing H x W x D (mm)
Weight
Voltage, Current, Operating Conditions
125x80x120
approx. 750 g
Power supply
Current consumption:
–from the
–from the external 24 V supply:
Permitted ambient temperature Specifications according to /7/ must be adhered to when operating an
–horizontal installation
–vertical installation
5 V DC +/– 5%
24 V DC +/– 5%
70mA 0.6 A.
0 to 60° C
0 to 40° C
Altitude
up to 3000m above sea level
All the information in /7/ in the Section ”General Technical Data” regarding the following topics also applies to the CP
SElectromagnetic compatibility
STransportation and storage conditions
SMechanical and climatic ambient conditions
SInsulation tests, class of protection and degree of protection
Product information CP | 15 |
|