Tascam MD-301mkII user service Recording an MD, To protect an MD against accidental erasure

Page 8

Recording

Buttons used on this page

Notes on Recording

ªTo protect an MD against accidental erasure

After recording an MD, slide the record- protect tab to open the hole.

To record on the MD again, slide the tab to close the hole.

Recording an MD

1. Press the [POWER] button.

"NO DISC" appears on the display.

Turn on the source component and the amplifier. Set the input selector to the source component.

2. Insert a recordable MD.

Hold the MD with the label side up.

Insert in the direction of the arrow.

When a blank MD is inserted, the display shows "Disc Loading", "TOC Reading", "No Track !!" and "Blank Disc" in sequence.

When a partially recorded MD is inserted, the deck will automatically start recording from the end of the last recorded track.

3.Select the input with the [INPUT SELECTOR].

Display

Selected Input

ANALOG

ANALOG INPUT

DIGITAL 1

DIGITAL INPUT 1

 

(OPTICAL)

DIGITAL 2

DIGITAL IN 2 (OPTICAL)

 

(front panel)

4.Select the recording mode with the [REC MODE] switch.

When [STEREO] is selected, stereo recording will be performed.

When [MONO] is selected, monaural recording will be performed using only the left (L) channel. "L" appears on the level meter, but the output is sent to both channels.

The maximum amount of time available with monaural recording is twice that of stereo recording.

5. Press the [ºRECORD] button.

The deck enters the Record-Ready mode

(" " lights up).

"Disc Full !!" or "Track Full !!" is displayed when no room is available on the MD for recording.

6. Adjust the recording level.

If [ANALOG] was selected above, adjust the recording level with the [INPUT] control.

When adjusting the recording level, adjust so that the "OVER" segments of the peak level meter do not light up.

7.Start recording.

Press the [¥PLAY] button or the [π READY] button ( "¥ " lights up). Start playing the source program.

8.To stop recording, press the [ª STOP] button.

ªTo stop recording temporarily (ready) Press the [π READY] button.

Press the [¥PLAY] or [π READY] button to resume recording.

Whenever you pause recording, the track number increases by one.

ªTo eject the MD

Press the [ø EJECT] button.

If the power is turned off with the MD left

in the deck (" " lights up) after recording, the UTOC cannot be recorded. Turn the power back on within 3 or 4 days and eject the MD. The recorded data might be lost if the MD is left in the deck for a long time.

– 8 –

ªWhen "Disc Full !!" or "Track Full !!" is displayed

The MD has no more available space for recording or the MD has used up all its track numbers. Erase unnecessary tracks or record music on another MD.

ªThe way track numbers are assigned varies depending on the source

When a CD or MD is played and recorded digitally by selecting [DIGITAL 1/2] with the

[INPUT SELECTOR]:

Track numbers on the recorded MD are assigned to match those on the source CD or MD. However, in the circum- stances listed below only one track number may be assigned to a recorded section.

·A section composed of the repeated playback of a single track on a disc (e.g. using single track repeat playback).

·A section composed of the succes- sive recording of tracks with the same track number from more than one disc. Also, if the source is an MD, track numbers may not be marked for

tracks shorter than 3 seconds.

When the source is recorded with [ANALOG] or when a digital source other than a CD or MD is recorded with [DIGITAL 1] or [DIGITAL 2] while the Auto Track function is OFF:

The entire recording may be counted as a single track with only one track number assigned to it.

·Track numbers can be assigned manually at the desired points by pressing the [º RECORD] button during recording.

·Track numbers can be assigned automatically by switching the Auto Track function to "A_TRACK > ON" before starting recording.

Image 8
Contents MD-301@# Important Safety Instructions Label required in this reguration is shown Optical pickup Type KMS-260AManufacturer Laser output 55 mW Wavelength 785 ±20 nmContents Before UseWhen Protected !! is displayed When D-IN Unlock ! blinksRemote Control Unit Handling MDsConnections Rack MountingVoltage Conversion ConnectionName of Each Control ªSTOP button p ¥PLAY button a πREADY buttonNumeric buttons 1 to 9, 0, +10 g REPEAT/A-B buttons Sync Record button Upper/Lower case button Aß∑aRecording Recording an MDTo protect an MD against accidental erasure Display Selected InputHeadphones PlaybackNormal Playback To play a track located before or after Current trackMonitoring the Input Signal Adjusting the Recording LevelUseful Tips for Recording Assigning Track Numbers During RecordingTimer Recording Sync RecordingChecking the Remaining MD Recording Time Checking the Recorded TracksUsing the Display Window Useful Tips for PlaybackSelecting the Desired Track Playing Tracks in Random Order Shuffle PlaybackWhen Recording to Analog Tape Timer Playback Repeating Tracks Repeat PlaybackEditing Recorded MDs Erasing Tracks Erase FunctionCombining Tracks Combine Function Moving a Track Move FunctionExample Combining B and C Example To move D from track number 4 to track numberAssigning Titles Title Function Press the Display button to select the character typeChanging entered characters Copying a Title Title Copy FunctionTitle entry keys Optional Functions System RestrictionsªEditing keys Display Messages … Rule Guide to the Serial Copy Management SystemSerial Copy Management System TOC TroubleshootingSpecifications To the User