AMX MVP-5200i manual How to Upload a Certificate File

Page 178

Appendix B: Wireless Technology

How to Upload a Certificate File

1.Install the latest AMX USB LAN LINK driver onto your computer by installing the latest versions of either TPDesign4 or NetLinx Studio2. This USB driver prepares your computer for proper communication with the MVP-5200i.

Refer to Step 1 from within the previous Step 1: Setup the Panel and PC for USB

Communication section on page 168.

2.Access the target panel's Protected Setup firmware page and configure the USB communication parameters.

Refer to Step 2 from within the previous Step 2: Confirm the Installation of the USB Driver on the PC section on page 169.

3.With the panel successfully communicating with the target computer, launch the Certificate Upload Utility.

Familiarize yourself with the Certificate Utility User Interface options.

4.Locate your certificate file by using the Browse button and navigating to the desired file type.

5.Use the drop-down arrow in the Local Address field to select direct communication through the USB port.

6.Select the 10.XX.XX.1 IP Address that corresponds to the virtual IP Address assigned to the USB connection port on the computer.

7.Navigate to the Add IP Address field at the bottom-right of the interface and enter a value of 1 greater than the virtual USB IP Address.

For example: If the virtual USB IP Address is 10.0.0.1, then add an address for the directly connected panel of 10.0.0.2. This is one greater than the USB address value detected by the utility.

A certificate may be sent to ONLY ONE directly connected panel via USB. Use the

Ethernet port’s IP Address to send a server certificate to multiple panel targets.

8.Select the IP Address which corresponds to the local computer's Ethernet address.

9.Navigate to the Add IP Address field (bottom-right of the interface) and enter the IP Addresses of the various target touch panels.

10.Click the Add button to complete the entry and add the new IP Address to the listing of available device IP Addresses. Repeat this process for all subsequent device IP Addresses.

11.Once the list is complete, click on the File drop-down menu and select the Save option. This launches a Save dialog to assign a name to the current list of addresses and then save the information as a TXT (text) file to a known location.

This application must be run from a local machine and should not be used from a remote network location.

12.Select the target devices to be uploaded with the selected certificate. These may be: individually selected by toggling the box next to the Send entry (with the Type column).

selected as a group by clicking on the Check All radio box located at the top of the device IP Address listing.

13.When ready to send the certificate file to the selected panels, click the Send button to initiate the upload.

Once the Status field for each entry reads Done, the upload was successfully completed.

170

MVP-5200i Modero Viewpoint Widescreen Touch Panel

Image 178
Contents MVP-5200i AMX Limited Warranty and Disclaimer Software License and Warranty Agreement Page Table of Contents Configuring Communication Programming Appendix a Text Formatting 155 Introduction MVP-5200i Specifications FG5966-01, FG5966-02 Panel LCD Parameters Included AccessoriesMemory External ComponentsMemory Table Charging Station Connector LocationsOther AMX Equipment Navigation Wheel Basic OperationIntercom Microphone Stylus Kick Stand Power ManagementCleaning the Touch Overlay, Case, and Navigation Wheel Audio/Video CapabilitiesMVP-TCS-52 Specifications Powering the MVP-TCS-52Table Charging Station Cleaning the MVP-TCS-52 Connections and WiringRecharging MVP-WCS-52 Specifications Wall Charging StationFront Panel ComponentsUnlocking the touch panel RechargingInstalling the MVP-WCS-52 Installing the Plastic Conduit BoxAll lockdown wings folded flat during installation Tie-Wrap Anchors Mini-Captive Wire Connector Plug female MVP-WCS-52 Installing the Optional Metal Conduit Box Typical Metal Conduit Box InstallationConfiguring Communication IR Communication IR transmitter window on the MVP-5200i-GWModero Setup and System Settings Accessing the Setup and Protected Setup PagesWireless Settings Wireless Access Overview Setting the Panel’s Device NumberConfigure the Device’s Wireless IP Settings Configuring Wireless Network AccessWireless communication using a Dhcp Address Wireless communication using a Static IP Address Using the Site Survey tool Site SurveyConfiguring Communication Configure the Card’s Wireless Security Settings Site Survey of available Waps Unsecured WAP shown selectedSame as Abc Automatically setting Ssid Manually setting SsidRequired Information WEP Passphrase Keyboard Configuring Communication Choose a Master Connection Mode Ethernet over USBTouch panel setup Found New Hardware Wizard dialogue boxNext box , make sure to Completing the Found New Hardware Wizard Configure a Virtual NetLinx Master using NetLinx Studio Select Use the following IP AddressCommunications Settings dialog box Ethernet Mode Description ProceduresConnection Modes Master Connection to a Virtual Master via Ethernet Start Run cmd command Ethernet Using G4 Web Control to Interact with a G4 Panel G4 Web ControlConfiguring Communication Using the NetLinx Master to control the G4 panel Web Control VNC installation and Password entry screens Configuring Communication Page Setup Setup PagesNavigation Buttons Connection Status Display TimeoutTimeout Inactivity Page FlipProtected Setup Pages Navigation ButtonsProject Information Information ButtonProject Information AMX IR 38K Assigned Sales OrderPurchase Order PortPanel Information Panel InformationTime & Date Settings Time & Date SetupMaster Volume Audio SettingsAudio Settings Default Panel SoundsSupported WAV Sample Rates WAV files Supported sample ratesAnalog Battery Settings BatteryBattery Power Brightness Limit Page Device Number Protected SetupOptions Reboot/Shutdown Panel System RecoveryDocking Station Protected Setup Navigation Buttons Protected Setup Navigation ButtonsIP Settings System SettingsSystem Settings Page Elements Master ConnectionSystem Setting Page Elements Ethernet Only disabled when USB is selectedWireless Settings Wireless SettingsAddress Access Point MACWireless Security Network Name Ssid WAP namesEAP-TLS RF Link InfoWireless Security Support Wireless Security802.11g Wi-Fi CF card Open Clear Text Settings Open Clear Text SettingsSave/Cancel Static WEP Settings Static WEP SettingsWEP 64 / WEP Generate Passphrase Default KeyAuthentication WEP KeysWPA-PSK Settings WPA-PSK SettingsPassword/Pass Phrase EAP Security & Server Certificates Overview EAP-PEAP EAP-TTLS EAP-TLSEAP-LEAP Settings Wireless Settings page EAP-LEAP SettingsPassword EAP-LEAP SettingsIdentity EAP-FAST Settings EAP-FAST SettingsAutomatic PAC Been DisabledAnonymous Identity ProvisioningEAP-PEAP Settings Wireless Settings page EAP-PEAP SettingsCertificate Authority EAP-PEAP SettingsInner Authentication Type Peap VersionEAP-TTLS Settings EAP-TTLS SettingsSsid Service Set Identifier Anonymous@amx.com EAP-TLS Settings EAP-TLS SettingsClient Certificate Private Key passwordPrivate Key Certificates and their Extensions Client certificate configurationClient Certificate Configuration Certificate Types Supported by the Modero FirmwareCalibration CalibrationG4 Web Control Timeout G4 Web Control SettingsG4 Web Control Settings G4 Web ControlProtected Setup Pages Cache Settings Other SettingsCache Settings Image Cache SettingsPassword Settings Password SetupProtected Setup Pages Panel Connection Logs ToolsPanel Connection Logs Panel Statistics Panel StatisticsConnection Utility Connection UtilityConfigure the panel for a USB Connection Type Scale Images For Setup PagesUpgrading the Modero Firmware via the USB port Prepare Studio for communication via the USB port Confirm and Upgrade the firmware via the USB port Upgrading Firmware Using USB for a Virtual Master transfer Special Note for Network Interface Connections Network Connections windowAdvanced Settings window 100 MVP-5200i Modero Viewpoint Widescreen Touch Panel Overview CommandsCommands Navigation Wheel Programming@PHE @DPG@PDR @PHPCommands @PPT @PPM@PPN @PPX@PSP @PSE@PST Ppog PpofPpon RGB Values for all 88 Basic Colors Programming NumbersRGB triplets and names for basic 88 colors Index No Name Red Green Blue108 MVP-5200i Modero Viewpoint Widescreen Touch Panel Font styles and ID numbers Default Font Styles and ID NumbersFont ID Font type Size TPD4 Border Styles by Name Border styles and Programming numbersBorder Styles and Programming Numbers Border stylesMVP-5200i Modero Viewpoint Widescreen Touch Panel 111 112 MVP-5200i Modero Viewpoint Widescreen Touch Panel ANI Button CommandsButton Commands APFBCB BAUBCF BDO BCTBFB Entry is required BIMBLN Sendcommand Panel,BMC-150,1,1,315,1,%BR%FT%TX%BM%IC%CF%CT BMCBMF BMF-vt addr range,button states range,dataCont BMP BMIBML BNCBNT BNNBOP BOS BORBPP BSM BRDBSF BSOBVP BVLBVN BVTDPF CPFDLD ENAGDI FONGIV GRD GLHGLL GRUICO GSNIRM JSB JSIPass data JSTMBT MDCEffect names TECTEF TXTMiscellaneous MVP Strings back to the Master MVP Panel Lock Passcode commandsMVP Panel Lock Passcode Commands MVP Strings to MasterLPR Text Effects NamesText Effects LPSButton Query Commands DefineeventCustom Event Fields Button Query CommandsSend Command Panel,?BCB-529,1 ?BCB?BCF ?BCT?BMP ?BOP?BRD ?BWW?FON ?ICO?JSB ?JSI?JST ?TEC?TEF Send Command Panel,?TEF-529,1Send Command Panel,?TXT-529,1 ?TEF-vt addr range,button states rangePanel Runtime Operation Commands Panel Runtime OperationsBeep @AKP@AKR BritPkeyp Setup@EKP @PKPTpageon @SOU@TKP TpageoffCAL Input CommandsInput Commands KPSEmbedded Codes Embedded codesDecimal numbers Hexidecimal values Virtual keystroke Panel Setup Commands Panel Setup CommandsDynamic Image Commands Dynamic Image CommandsRAF-resource name,data Host ’%Hhost’ File ’%Ffile’ DescriptionPage Battery Life and Replacement Battery Replacement Screw placement at the back of the MVP-5200i- GWMVP-5200i Modero Viewpoint Widescreen Touch Panel 155 Page Formatting Code Operations Text Formatting Codes for Bargraphs/JoysticksBargraph Text Code Inputs ExampleCharacter Types Text Area Input MaskingInput mask character types Character Masking RuleInput mask operations Input mask rangesInput mask next field characters Input mask literalsOutput Examples Input mask output examplesCommon Name Input Mask Escape Sequences URL ResourcesSpecial escape sequences Sequence Panel InformationAppendix B Wireless Technology Overview of Wireless TechnologyTerminology 802.1xWEP WPA2 EAP Method Characteristics EAP AuthenticationEAP characteristics Method Credential Type Authentication Pros ConsEAP communication overview LANSetup the Panel and PC for USB Communication Configuring your MVP-5200i for USB CommunicationAMX Certificate Upload Utility Confirm the Installation of the USB Driver on the PC How to Upload a Certificate File Battery Will Not Hold Or Take a Charge Panel Doesn’t Respond To TouchesMy WEP Doesn’t Seem To Be Working MVP-5200i Isn’t Appearing In The Online Tree TabMVP Can’t Obtain a Dhcp Address NetLinx Studio Only Detects One Of My Connected MastersOnly One Modero Panel In My System Shows Up Page Page It’s Your World Take Control