AMX MVP-5200i manual G4 Web Control Settings, G4 Web Control Timeout

Page 93

Protected Setup Pages

G4 Web Control Settings Page

An on-board VNC (Virtual Network Computing) server allows the panel to connect to any remote PC running a VNC client. Once connected, the client can view and control the panel remotely. The options on this page allow you to enable/disable G4 Web Control functionality(FIG. 74).

FIG. 74 G4 Web Control page

Features on this page include:

G4 Web Control Page

Back:

Saves all changes and returns to the previous page.

 

 

Connection Status icon:

The icon in the upper-right corner of each Protected Setup page provides a

 

constant visual indication of current connection status.

 

Note: a Lock appears on the icon if the panel is connected to a secured NetLinx

 

Master.

 

 

G4 Web Control Settings:

Sets the IP communication values for the touch panel:

Enable/Enabled

 

The Enable/Enabled button toggles between the two G4 activation settings:

 

Enable - deactivates G4 Web Control on the panel.

 

Enabled - activates G4 Web Control on the panel.

Network Interface Select

 

Toggles between the two network interface options:

 

Wireless - the panel is communicating via a Wireless Access Point (WAP).

 

• Wired - the panel is communicating via its mini-USB port.

Web Control Name

 

Use this field to enter a unique alpha-numeric string to be used as the panel’s

 

display name within the Manage WebControl Connections window of the

 

NetLinx Security browser window.

Web Control Password

 

Use this field to enter the G4 Authentication session password required for

 

VNC access to the panel.

Web Control Port

 

Use this field to enter the number of the port used by the VNC Web Server.

 

Default = 5900.

 

 

Maximum Number of

Displays the maximum number of users that can be simultaneously connected

Connections

to this panel via VNC. Default = 1.

Current Connection Count

 

Displays the number of users currently connected to this panel via VNC.

 

 

G4 Web Control Timeout:

Sets the length of time (in minutes) that the panel can remain idle, detecting no

 

cursor movements, before the G4 Web Control session is terminated.

 

• Minimum value = 0 minutes (panel never times out)

 

• Maximum value = 240 minutes (panel times out after 240 minutes)

 

 

MVP-5200i Modero Viewpoint Widescreen Touch Panel

85

 

 

Image 93
Contents MVP-5200i AMX Limited Warranty and Disclaimer Software License and Warranty Agreement Page Table of Contents Configuring Communication Programming Appendix a Text Formatting 155 Introduction MVP-5200i Specifications FG5966-01, FG5966-02 Memory Included AccessoriesPanel LCD Parameters External ComponentsTable Charging Station Connector Locations MemoryOther AMX Equipment Basic Operation Navigation WheelIntercom Microphone Cleaning the Touch Overlay, Case, and Navigation Wheel Power ManagementStylus Kick Stand Audio/Video CapabilitiesPowering the MVP-TCS-52 MVP-TCS-52 SpecificationsTable Charging Station Connections and Wiring Cleaning the MVP-TCS-52Recharging Wall Charging Station MVP-WCS-52 SpecificationsComponents Front PanelRecharging Unlocking the touch panelInstalling the Plastic Conduit Box Installing the MVP-WCS-52All lockdown wings folded flat during installation Tie-Wrap Anchors Mini-Captive Wire Connector Plug female MVP-WCS-52 Typical Metal Conduit Box Installation Installing the Optional Metal Conduit BoxConfiguring Communication IR transmitter window on the MVP-5200i-GW IR CommunicationAccessing the Setup and Protected Setup Pages Modero Setup and System SettingsSetting the Panel’s Device Number Wireless Settings Wireless Access OverviewConfiguring Wireless Network Access Configure the Device’s Wireless IP SettingsWireless communication using a Dhcp Address Wireless communication using a Static IP Address Site Survey Using the Site Survey toolConfiguring Communication Site Survey of available Waps Unsecured WAP shown selected Configure the Card’s Wireless Security SettingsSame as Abc Manually setting Ssid Automatically setting SsidRequired Information WEP Passphrase Keyboard Configuring Communication Ethernet over USB Choose a Master Connection ModeFound New Hardware Wizard dialogue box Touch panel setupNext box , make sure to Completing the Found New Hardware Wizard Select Use the following IP Address Configure a Virtual NetLinx Master using NetLinx StudioCommunications Settings dialog box Mode Description Procedures EthernetConnection Modes Master Connection to a Virtual Master via Ethernet Start Run cmd command Ethernet G4 Web Control Using G4 Web Control to Interact with a G4 PanelConfiguring Communication Using the NetLinx Master to control the G4 panel Web Control VNC installation and Password entry screens Configuring Communication Page Setup Pages SetupNavigation Buttons Timeout Display TimeoutConnection Status Inactivity Page FlipNavigation Buttons Protected Setup PagesInformation Button Project InformationProject Information Purchase Order Sales OrderAMX IR 38K Assigned PortPanel Information Panel InformationTime & Date Setup Time & Date SettingsAudio Settings Audio SettingsMaster Volume Default Panel SoundsWAV files Supported sample rates Supported WAV Sample RatesAnalog Battery Battery SettingsBattery Power Brightness Limit Page Protected Setup Device NumberOptions System Recovery Reboot/Shutdown PanelDocking Station Protected Setup Navigation Buttons Protected Setup Navigation ButtonsSystem Settings Page Elements System SettingsIP Settings Master ConnectionEthernet Only disabled when USB is selected System Setting Page ElementsWireless Settings Wireless SettingsWireless Security Access Point MACAddress Network Name Ssid WAP namesRF Link Info EAP-TLSWireless Security Wireless Security Support802.11g Wi-Fi CF card Open Clear Text Settings Open Clear Text SettingsSave/Cancel Static WEP Settings Static WEP SettingsWEP 64 / WEP Authentication Default KeyGenerate Passphrase WEP KeysWPA-PSK Settings WPA-PSK SettingsPassword/Pass Phrase EAP-PEAP EAP-TTLS EAP-TLS EAP Security & Server Certificates OverviewWireless Settings page EAP-LEAP Settings EAP-LEAP SettingsEAP-LEAP Settings PasswordIdentity EAP-FAST Settings EAP-FAST SettingsAnonymous Identity Been DisabledAutomatic PAC ProvisioningWireless Settings page EAP-PEAP Settings EAP-PEAP SettingsInner Authentication Type EAP-PEAP SettingsCertificate Authority Peap VersionEAP-TTLS Settings EAP-TTLS SettingsSsid Service Set Identifier Anonymous@amx.com EAP-TLS Settings EAP-TLS SettingsPrivate Key password Client CertificatePrivate Key Client Certificate Configuration Client certificate configurationCertificates and their Extensions Certificate Types Supported by the Modero FirmwareCalibration CalibrationG4 Web Control Settings G4 Web Control SettingsG4 Web Control Timeout G4 Web ControlProtected Setup Pages Cache Settings Other SettingsCache Settings Image Cache SettingsPassword Setup Password SettingsProtected Setup Pages Tools Panel Connection LogsPanel Connection Logs Panel Statistics Panel StatisticsConnection Utility Connection UtilityScale Images For Setup Pages Configure the panel for a USB Connection TypeUpgrading the Modero Firmware via the USB port Prepare Studio for communication via the USB port Confirm and Upgrade the firmware via the USB port Upgrading Firmware Using USB for a Virtual Master transfer Network Connections window Special Note for Network Interface ConnectionsAdvanced Settings window 100 MVP-5200i Modero Viewpoint Widescreen Touch Panel Commands CommandsOverview Navigation Wheel Programming@PDR @DPG@PHE @PHPCommands @PPN @PPM@PPT @PPX@PSE @PSP@PST Ppof PpogPpon RGB triplets and names for basic 88 colors Programming NumbersRGB Values for all 88 Basic Colors Index No Name Red Green Blue108 MVP-5200i Modero Viewpoint Widescreen Touch Panel Default Font Styles and ID Numbers Font styles and ID numbersFont ID Font type Size Border Styles and Programming Numbers Border styles and Programming numbersTPD4 Border Styles by Name Border stylesMVP-5200i Modero Viewpoint Widescreen Touch Panel 111 112 MVP-5200i Modero Viewpoint Widescreen Touch Panel Button Commands Button CommandsANI APFBAU BCBBCF BCT BDOBFB BIM Entry is requiredBLN BMC Sendcommand Panel,BMC-150,1,1,315,1,%BR%FT%TX%BM%IC%CF%CTBMF-vt addr range,button states range,data BMFCont BML BMIBMP BNCBNN BNTBOP BOR BOSBPP BSF BRDBSM BSOBVN BVLBVP BVTDLD CPFDPF ENAFON GDIGIV GLL GLHGRD GRUGSN ICOIRM JSI JSBMBT JSTPass data MDCTEF TECEffect names TXTMVP Panel Lock Passcode Commands MVP Panel Lock Passcode commandsMiscellaneous MVP Strings back to the Master MVP Strings to MasterText Effects Text Effects NamesLPR LPSDefineevent Button Query CommandsSend Command Panel,?BCB-529,1 Button Query CommandsCustom Event Fields ?BCB?BCT ?BCF?BOP ?BMP?BWW ?BRD?ICO ?FON?JSI ?JSB?TEC ?JSTSend Command Panel,?TXT-529,1 Send Command Panel,?TEF-529,1?TEF ?TEF-vt addr range,button states rangePanel Runtime Operations Panel Runtime Operation Commands@AKR @AKPBeep Brit@EKP SetupPkeyp @PKP@TKP @SOUTpageon TpageoffInput Commands Input CommandsCAL KPSEmbedded codes Embedded CodesDecimal numbers Hexidecimal values Virtual keystroke Panel Setup Commands Panel Setup CommandsDynamic Image Commands Dynamic Image CommandsHost ’%Hhost’ File ’%Ffile’ Description RAF-resource name,dataPage Battery Life and Replacement Screw placement at the back of the MVP-5200i- GW Battery ReplacementMVP-5200i Modero Viewpoint Widescreen Touch Panel 155 Page Bargraph Text Code Inputs Text Formatting Codes for Bargraphs/JoysticksFormatting Code Operations ExampleInput mask character types Text Area Input MaskingCharacter Types Character Masking RuleInput mask next field characters Input mask rangesInput mask operations Input mask literalsInput mask output examples Output ExamplesCommon Name Input Mask Special escape sequences URL ResourcesEscape Sequences Sequence Panel InformationOverview of Wireless Technology Appendix B Wireless Technology802.1x TerminologyWEP WPA2 EAP characteristics EAP AuthenticationEAP Method Characteristics Method Credential Type Authentication Pros ConsLAN EAP communication overviewConfiguring your MVP-5200i for USB Communication Setup the Panel and PC for USB CommunicationAMX Certificate Upload Utility Confirm the Installation of the USB Driver on the PC How to Upload a Certificate File Panel Doesn’t Respond To Touches Battery Will Not Hold Or Take a ChargeMVP Can’t Obtain a Dhcp Address MVP-5200i Isn’t Appearing In The Online Tree TabMy WEP Doesn’t Seem To Be Working NetLinx Studio Only Detects One Of My Connected MastersOnly One Modero Panel In My System Shows Up Page Page It’s Your World Take Control