Sony MDS-PC3 specifications Operating the Continuous Playback Mode

Page 21

4-5-1. Operating the Continuous Playback Mode

1.Entering the continuous playback mode

1Set the disc in the unit. (Whichever recordable discs or discs for playback only are available.) 2Rotate the AMS knob and display “CPLAY1MODE”(C34).

3Press the @/1 button to change the display to “CPLAY1 MID”.

4When access completes, the display changes to “C = AD = )”. Note : The numbers “ ” displayed show you error rates and ADER.

2.Changing the parts to be played back

1Press the @/1 button during continuous playback to change the display as below.

“CPLAY1 MID” t “CPLAY1 OUT” t “CPLAY1 IN”

When pressed another time, the parts to be played back can be moved.

2When access completes, the display changes to “C = AD = )”. Note : The numbers “ ” displayed show you error rates and ADER.

3.Ending the continuous playback mode

1Press the x/Z button. The display will change to “CPLAY1MODE”(C34).

2Press the x/Z“PGM” button to remove the disc.

Note : The playback start addresses for IN, MID, and OUT are as follows.

IN

40h cluster

MID

300h cluster

OUT

700h cluster

4-5-2. Operating the Continuous Recording Mode (Use only when performing self-recording/palyback check.)

1.Entering the continuous recording mode 1Set a recordable disc in the unit.

2Rotate the AMS knob and display “CREC 1MODE” (C35).

3Press the @/1 button to change the display to “CREC1 MID”.

4When access completes, the display changes to “CREC1 ( )” and REC lights up. Note : The numbers “ ” displayed shows you the recording position addresses.

2.Changing the parts to be recorded

1When the @/1 button is pressed during continuous recording, the display changes as below. “CREC1 MID” t “CREC1 OUT” t “CREC1 IN”

When pressed another time, the parts to be recorded can be changed. REC goes off.

2When access completes, the display changes to “CREC1 ( )” and REC lights up. Note : The numbers “ ” displayed shows you the recording position addresses.

3.Ending the continuous recording mode

1Press the x/Z button. The display changes to “CREC 1MODE” (C35 ) and REC goes off.

2Press the x/Z“PGM” button to remove the disc.

Note 1 : The recording start addresses for IN, MID, and OUT are as follows.

 

IN

40h cluster

 

MID

300h cluster

 

OUT

700h cluster

Note 2

: The

 

x/Z

button can be used to stop recording anytime.

Note 3

: Do not perform continuous recording for long periods of time above 5 minutes.

Note 4

: During continuous recording, be careful not to apply vibration.

21

Image 21
Contents MDS-PC3 SpecificationsTOC t Edit t TOC Edit t blank t SELF-DIAGNOSIS FunctionItems of Error History Mode Items and Contents Disassembly Table of ContentsDiagrams Table of Error CodesSection Service Notes Flexible Circuit Board RepairingLead free soldering JIG for Checking BD Board Waveform Record Precedure Checks Prior to Parts Replacement and Adjustments Forced ResetMain Board Component Side Bit Binary Retry Cause Display ModeHexadecimal t Binary Conversion Table General Section Remote Parts DescriptionUsing the Display Hooking Up MD Mechanism Deck MDM-7A Section DisassemblyOver Light Head HR901, BD MD Board Main BoardLoading Motor Assy M103 Holder AssyOptical PICK-UP MD KMS-260B/JIN Sled Motor Assy M102, SliderSpindle Motor Assy M101 Precautions for USE of Test Mode Section Test ModeSetting the Test Mode Exiting the Test ModeDisplay Details Mark Group Selecting the Test ModeOperating the Continuous Playback Mode Mode display Test Mode DisplaysError rate display Functions of Other ButtonsMeanings of Other Displays Automatic SELF-DIAGNOSIS FunctionInformation Section Electrical Adjustments Parts Replacement and AdjustmentCheck before replacement Adjustment flow Precautions for Checking Laser Diode Emission Precautions for USE of Optical PICK- UP KMS-260BPrecautions for Adjustments Checks Prior to Repairs Using the Continuously Recorded DiscOther Checks Auto CheckCD Error Rate Check Play Check MO Error Rate CheckInitial Setting of Adjustment Value Temperature Compensation Offset AdjutmentLaser Power Adjustment Iop NV Save Traverse AdjustmentFocus Bias Adjustment Auto Gain Control Output Level Adjustment Error Rate CheckCD Auto Gain Control Output Level Adjustment MO Auto Gain Control Output Level AdjustmentAdjusting Points and Connecting Points Diagrams MDS-PC3 Block Diagrams BD SectionSclk Cclk Main SectionSemiconductor Printed Wiring Board BD SectionPIN Function MDS-PC3 Printed Wiring Board Main Section PIN Functon MDS-PC3 Printed Wiring Board Panel Section Schematic Diagram Panel Section See page 35 for Waveforms IC101 CXA2523AR BD Board IC Block DiagramsLB1830M-S-TE-L Main Board BH3541F-E2 Main Board IC101 CXA2523AR RF Amplifier BD Board IC PIN FunctionsMNT0 FOK Mvci IC300 M30805SGP Main Board Shck MNT1 Chassis Section Section Exploded Views319 302 320 317 304 308 303 305 306 301 318 307 Mechanism MDM-7A351 MechanismRemarks Ref. No Description Section Electrical Parts ListMetal Chip Main PIN, Connector 2P Diode Main Panel KEY REFLECT/PROTECT SW MDS-PC3 Panel