5-6-4. Auto Check
This test mode performs CREC and CPLAY automatically for mainly checking the characteristics of the optical
Procedure
1.Press the @/1 button. If “LDPWR minicheck” is displayed, it means that the laser power check has not been performed. In this case, perform the laser power check and Iop compare, and then repeat from step 1.
2.If a disc is in the mechanical deck, it will be ejected forcibly. “DISC IN” will be displayed in this case. Load a test disc (MDW-
3.If a disk is loaded at step 2, the check will start automatically.
4.When “XX CHECK” is displayed, the item corresponding to XX will be performed.
When “06 CHECK” completes, the disc loaded at step 2 will be ejected. “DISC IN” will be displayed. Load the check disc (MD)
5.When the disc is loaded, the check will automatically be resumed from “07 CHECK”.
6.After completing to test item 12, check OK or NG will be displayed. If all items are OK, “CHECK ALL OK” will be displayed. If any item is NG, it will be displayed as “NG:xxxx”.
When “CHECK ALL OK” is displayed, it means that the optical
When displayed as “NG:xxxx”, it means that the optical
5-6-5. Other Checks
All the following checks are performed by the Auto Check mode. They therefore need not be performed in normal operation.
Connection :
Oscilloscope
BD board
CN105 pin 4 (TE)
CN105 pin 6 (VC)
V : 0.5 V/div
H : 10 ms/div
Input : DC mode
Checking Procedure:
1.Connect an oscilloscope to CN105 pin 4 (TE) and CN105 pin 6 (VC) of the BD board.
2.Load a test disc
3.Rotate the AMS knob and display “EF MO CHECK” (C14).
4.Press the @/1 button and display “EFB =
(Laser power READ power/Focus servo ON/tracking servo OFF/ spindle (S) servo ON)
5.Observe the waveform of the oscilloscope, and check that the specified value is satisfied. Do not rotate the AMS knob. (Read power traverse checking)
(Traverse Waveform)
A
VC
B
Specified value : Below 10% offset value
Offset value (%) = IA – BI X 100 2 (A + B)
6.Press the @/1 button and display “EFB =
7.Observe the waveform of the oscilloscope, and check that the specified value is satisfied. Do not rotate the AMS knob. (Write power traverse checking)
(Traverse Waveform)
A
VC
B
Specified value : Below 10% offset value
Offset value (%) = IA – BI X 100 2 (A + B)
8. Press the @/1 button display “EFB =
Then, the optical
9.Observe the waveform of the oscilloscope, and check that the specified value is satisfied. Do not rotate the AMS knob.
(Traverse Waveform)
A
VC
B
Specified value : Below 10% offset value
Offset value (%) = IA – BI X 100 2 (A + B)
10.Press the @/1 button display “EF MO CHECK” (C14) The disc stops rotating automatically.
11.Press the x/Z “PGM” button and remove the disc.
12.Load the check disc (MD)
13.Roteto the AMS knob and display “EF CD CHECK” (C15).
14. Press the @/1 button and display “EFB = CD”. Servo is imposed automatically.
28