5-14. ERROR RATE CHECK

5-14-1. CD Error Rate Check

Checking Procedure :

1.Load a check disc (MD) TDYS-1.

2.Rotate the AMS knob and display “CPLAY1MODE” (C34).

3.Press the @/1 button twice and display “CPLAY1 MID”.

4.The display changes to “C = AD = )”.

5.Check that the C1 error rate is below 20.

6.Press the x/Z button, stop playback, press the x/Z “PGM” button, and remove the test disc.

5-14-2. MO Error Rate Check

Checking Procedure :

1.Load a continuously recorded test disc (MDW-74/GA-1). (Refer to “5-5. Using the Continuously Recorded Disc”.)

2.Rotate the AMS knob and display “CPLAY1MODE” (C34).

3.Press the @/1 button and display “CPLAY1 MID”.

4.The display changes to “C = AD = )”.

5.If the C1 error rate is below 20, check that ADER is 00.

6.Press the x/Z button, stop playback, press the x/Z “PGM” button, and remove the test disc.

5-15. FOCUS BIAS CHECK

Change the focus bias and check the focus tolerance amount.

Checking Procedure :

1.Load a continuously recorded test disc (MDW-74/GA-1). (Refer to “5-5. Using the Continuously Recorded Disc”.)

2.Rotate the AMS knob and display “CPLAY1MODE” (C34).

3.Press the @/1 button twice and display “CPLAY1 MID”.

4. Press the

x/Z

button when “C =

AD = )” is dis-

played.

 

5.Rotate the AMS knob and display “FBIAS CHECK” (C16).

6.Press the @/1 button and display “ / c = ”.

The first four digits indicate the C error rate, the two digits after [/] indicate ADR, and the 2 digits after [c =] indicate the focus bias value.

Check that the C error is below 20 and ADER is below 2.

7.Press the @/1 button and display “ / b = ”. Check that the C error is below 100 and ADER is below 2.

8.Press the @/1 button and display “ / a = ”. Check that the C error is below 100 and ADER is below 2

9.Press the x/Z button, next press the x/Z “PGM” button, and remove the continuously recorded disc.

Note 1 : If the C error and ADER are above other than the speci- fied value at points a (step 8. in the above) or b (step 7. in the above), the focus bias adjustment may not have been carried out properly. Adjust perform the beginning again.

5-16. AUTO GAIN CONTROL OUTPUT LEVEL ADJUSTMENT

Be sure to perform this adjustment when the optical pick-up is re- placed.

If the adjustment results becomes “Adjust NG!”, the optical pick- up may be faulty or the servo system circuits may be abnormal.

5-16-1. CD Auto Gain Control Output Level Adjustment

Adjusting Procedure :

1.Insert the check disc (MD) TDYS-1.

2.Rotate the AMS knob to display “AG Set (CD)” (C11).

3.When the @/1 button is pressed, the adjustment will be performed automatically.

“Complete! !” will then be displayed momentarily when the value is recorded in the non-volatile memory, after which the display changes to “AG Set (CD)” (C11).

4.Press the x/Z “PGM” button to remove the disc.

5-16-2. MO Auto Gain Control Output Level Adjustment

Adjusting Procedure :

1.Insert the reference disc (MDW-74/GA-1) for recording.

2.Rotate the AMS knob to display “AG Set (MO)” (C10).

3.When the @/1 button is pressed, the adjustment will be performed automatically.

“Complete! !” will then be displayed momentarily when the value is recorded in the non-volatile memory, after which the display changes to “AG Set (MO)” (C10).

4.Press the x/Z “PGM” button to remove the disc.

33

Image 33
Contents MDS-PC3 SpecificationsTOC t Edit t TOC Edit t blank t SELF-DIAGNOSIS FunctionItems of Error History Mode Items and Contents Disassembly Table of ContentsDiagrams Table of Error CodesSection Service Notes Flexible Circuit Board RepairingLead free soldering JIG for Checking BD Board Waveform Record Precedure Checks Prior to Parts Replacement and Adjustments Forced ResetMain Board Component Side Bit Binary Retry Cause Display ModeHexadecimal t Binary Conversion Table General Section Remote Parts DescriptionUsing the Display Hooking Up MD Mechanism Deck MDM-7A Section DisassemblyOver Light Head HR901, BD MD Board Main BoardLoading Motor Assy M103 Holder AssyOptical PICK-UP MD KMS-260B/JIN Sled Motor Assy M102, SliderSpindle Motor Assy M101 Precautions for USE of Test Mode Section Test ModeSetting the Test Mode Exiting the Test ModeDisplay Details Mark Group Selecting the Test ModeOperating the Continuous Playback Mode Mode display Test Mode DisplaysError rate display Functions of Other ButtonsMeanings of Other Displays Automatic SELF-DIAGNOSIS FunctionInformation Section Electrical Adjustments Parts Replacement and AdjustmentCheck before replacement Adjustment flow Precautions for Checking Laser Diode Emission Precautions for USE of Optical PICK- UP KMS-260BPrecautions for Adjustments Checks Prior to Repairs Using the Continuously Recorded DiscOther Checks Auto CheckCD Error Rate Check Play Check MO Error Rate CheckInitial Setting of Adjustment Value Temperature Compensation Offset AdjutmentLaser Power Adjustment Iop NV Save Traverse AdjustmentFocus Bias Adjustment Auto Gain Control Output Level Adjustment Error Rate CheckCD Auto Gain Control Output Level Adjustment MO Auto Gain Control Output Level AdjustmentAdjusting Points and Connecting Points Diagrams MDS-PC3 Block Diagrams BD SectionSclk Cclk Main SectionSemiconductor Printed Wiring Board BD SectionPIN Function MDS-PC3 Printed Wiring Board Main Section PIN Functon MDS-PC3 Printed Wiring Board Panel Section Schematic Diagram Panel Section See page 35 for Waveforms IC101 CXA2523AR BD Board IC Block DiagramsLB1830M-S-TE-L Main Board BH3541F-E2 Main Board IC101 CXA2523AR RF Amplifier BD Board IC PIN FunctionsMNT0 FOK Mvci IC300 M30805SGP Main Board Shck MNT1 Chassis Section Section Exploded Views319 302 320 317 304 308 303 305 306 301 318 307 Mechanism MDM-7A351 MechanismRemarks Ref. No Description Section Electrical Parts ListMetal Chip Main PIN, Connector 2P Diode Main Panel KEY REFLECT/PROTECT SW MDS-PC3 Panel