15.Observe the waveform of the oscilloscope, and check that the specified value is satisfied. Do not rotate the AMS knob.

(Traverse Waveform)

A

VC

B

Specified value : Below 10% offset value

Offset value (%) = IA – BI X 100 2 (A + B)

16.Press the @/1 button and display “EF CD CHECK” (C15).

17.Press the x/Z “PGM” button and remove the check disc (MD) TDYS-1.

Note 1 : MO reading data will be erased during if a recorded disc is used in this adjustment.

Note 2 : If the traverse waveform is not clear, connect the oscillo- scope as shown in the following figure so that it can be

seen more clearly.

Oscilloscope

 

BD board

330 k

CN105 pin 4 (TE)

10pF

CN105 pin 6 (VC)

 

5-6-7. Focus Bias Check

Change the focus bias and check the focus tolerance amount.

Checking Procedure :

1.Load a continuously recorded test disc (MDW-74/GA-1). (Refer to “5-5. Using the Continuously Recorded Disc”.)

2.Rotate the AMS knob and display “CPLAY1MODE” (C34).

3.Press the @/1 button and display “CPLAY1 MID”.

4. Press the

x/Z

button when “C =

AD = )” is dis-

played.

 

5.Rotate the AMS knob and display “FBIAS CHECK” (C16).

6.Press the @/1 button and display “ / c = )”.

The first four digits indicate the C1 error rate, the two digits after [/] indicate ADER, and the 2 digits after [c =] indicate the focus bias value.

Check that the C1 error is below 20 and ADER is below 2.

7.Press the @/1 button and display “ / b = )”. Check that the C1 error is below 100 and ADER is below 2.

8.Press the @/1 button and display “ / a = )”. Check that the C1 error is below 100 and ADER is below 2.

9.Press the x/Z button, next press the A button, and remove the test disc.

5-6-8. C PLAY Check

MO Error Rate Check

Checking Procedure :

1.Load a continuously recorded test disc (MDW-74/GA-1). (Refer to “5-5. Using the Continuously Recorded Disc”.)

2.Rotate the AMS knob and display “CPLAY1MODE” (C34).

3.Press the @/1 button and display “CPLAY1 MID”.

4.The display changes to “C = AD = )”.

5.If the C1 error rate is below 20, check that ADER is 00.

6.Press the x/Z button, stop playback, press the x/Z “PGM” button, and test disc.

CD Error Rate Check

Checking Procedure :

1.Load a check disc (MD) TDYS-1.

2.Rotate the AMS knob and display “CPLAY1MODE” (C34).

3.Press the @/1 button twice and display “CPLAY1 MID”.

4.The display changes to “C = AD = )”.

5.Check that the C1 error rate is below 20.

6.Press the x/Z button, stop playback, press the x/Z “PGM” button, and the test disc.

5-6-9. Self-Recording/playback Check

Prepare a continuous recording disc using the unit to be repaired and check the error rate.

Checking Procedure :

1.Insert a recordable test disc (MDW-74/GA-1) into the unit.

2.Rotate the AMS knob to display “CREC 1MODE” (C35).

3.Press the @/1 button to display the “CREC1 MID”.

4.When recording starts, “ REC ” is displayed, this becomes “CREC1 (@@@@)” (@@@@ is the address), and recording starts.

5.About 1 minute later, press the x/Z button to stop continuous recording.

6.Rotate the AMS knob to display “CPLAY 1MODE” (C34).

7.Press the @/1 button to display “CPLAY1 MID”.

8.“C = AD = )” will be displayed.

9.Check that the C1 error becomes below 20 and the AD error below 2.

10.Press the x/Z button to stop playback, and press the x/Z“PGM” button and remove the disc.

29

Image 29
Contents MDS-PC3 SpecificationsTOC t Edit t TOC Edit t blank t SELF-DIAGNOSIS FunctionItems of Error History Mode Items and Contents Disassembly Table of ContentsDiagrams Table of Error CodesLead free soldering Section Service NotesFlexible Circuit Board Repairing JIG for Checking BD Board Waveform Record Precedure Main Board Component Side Checks Prior to Parts Replacement and AdjustmentsForced Reset Bit Binary Retry Cause Display ModeHexadecimal t Binary Conversion Table General Section Remote Parts DescriptionUsing the Display Hooking Up MD Mechanism Deck MDM-7A Section DisassemblyOver Light Head HR901, BD MD Board Main BoardLoading Motor Assy M103 Holder AssyOptical PICK-UP MD KMS-260B/JIN Sled Motor Assy M102, SliderSpindle Motor Assy M101 Precautions for USE of Test Mode Section Test ModeSetting the Test Mode Exiting the Test ModeDisplay Details Mark Group Selecting the Test ModeOperating the Continuous Playback Mode Mode display Test Mode DisplaysError rate display Functions of Other ButtonsInformation Meanings of Other DisplaysAutomatic SELF-DIAGNOSIS Function Check before replacement Section Electrical AdjustmentsParts Replacement and Adjustment Adjustment flow Precautions for Adjustments Precautions for Checking Laser Diode EmissionPrecautions for USE of Optical PICK- UP KMS-260B Checks Prior to Repairs Using the Continuously Recorded DiscOther Checks Auto CheckCD Error Rate Check Play Check MO Error Rate CheckLaser Power Adjustment Initial Setting of Adjustment ValueTemperature Compensation Offset Adjutment Iop NV Save Traverse AdjustmentFocus Bias Adjustment Auto Gain Control Output Level Adjustment Error Rate CheckCD Auto Gain Control Output Level Adjustment MO Auto Gain Control Output Level AdjustmentAdjusting Points and Connecting Points Diagrams MDS-PC3 Block Diagrams BD SectionSclk Cclk Main SectionSemiconductor Printed Wiring Board BD SectionPIN Function MDS-PC3 Printed Wiring Board Main Section PIN Functon MDS-PC3 Printed Wiring Board Panel Section Schematic Diagram Panel Section See page 35 for Waveforms IC101 CXA2523AR BD Board IC Block DiagramsLB1830M-S-TE-L Main Board BH3541F-E2 Main Board IC101 CXA2523AR RF Amplifier BD Board IC PIN FunctionsMNT0 FOK Mvci IC300 M30805SGP Main Board Shck MNT1 Chassis Section Section Exploded Views319 302 320 317 304 308 303 305 306 301 318 307 Mechanism MDM-7A351 MechanismRemarks Ref. No Description Section Electrical Parts ListMetal Chip Main PIN, Connector 2P Diode Main Panel KEY REFLECT/PROTECT SW MDS-PC3 Panel