Fluid Plate Events and Errors

 

 

MB3_

98

Maintenance due

Maintenance due on

 

Advisory

The active time total-

Service Component

 

 

- V3 Orbiter

valve 3 swirl orbiter

 

 

 

izer for the swirl dis-

 

 

 

 

 

 

 

 

penser associated

If necessary, reset

 

 

 

 

 

 

 

with this valve and

totalizer

 

 

 

 

 

 

 

fluid plate exceeded

 

 

 

 

 

 

 

 

limit setting

 

 

 

 

 

 

 

 

 

 

MB4_

99

Maintenance due

Maintenance due on

 

Advisory

The active time total-

Service Component

 

 

- V4 Orbiter

valve 4 swirl orbiter

 

 

 

izer for the swirl dis-

 

 

 

 

 

 

 

 

penser associated

If necessary, reset

 

 

 

 

 

 

 

with this valve and

totalizer

 

 

 

 

 

 

 

fluid plate exceeded

 

 

 

 

 

 

 

 

limit setting

 

 

 

 

 

 

 

 

 

 

Swirl Events and Errors

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Event

Gateway

 

Event

 

 

 

 

 

Code

Error No.

Event Name

Description

 

Event Type

 

Cause

Solution

 

 

 

 

 

 

 

 

 

 

 

Swirl Events and Errors

 

 

CBR_

---

Swirl Communi-

Swirl communication

 

Alarm

 

The ADM lost commu-

Restore communica-

 

 

cation Error

error with ADM

 

 

 

nication with the Swirl

tions

 

 

 

 

 

 

 

Control DGM

 

 

 

 

 

 

 

 

 

 

CDR_

---

Duplicate Module

Duplicate Swirl Control

 

Alarm

 

Two or more Swirl

Verify that all Swirl

 

 

 

DGM Detected

 

 

 

Control DGMs have

Control DGMs have

 

 

 

 

 

 

 

the same rotary switch

proper rotary switch

 

 

 

 

 

 

 

setting

settings. Reset mod-

 

 

 

 

 

 

 

 

ule after changing

 

 

 

 

 

 

 

 

rotary switch setting.

 

 

 

 

 

 

 

 

Refer to Swirl Control

 

 

 

 

 

 

 

 

DGM section, page 19.

 

 

 

 

 

 

 

 

 

EAD_

---

Maintenance

Maintenance mode

 

Advisory

 

Swirl maintenance

No action required

 

 

Mode Entered

entered

 

(self-clear-

 

mode entered

 

 

 

 

 

 

ing)

 

 

 

 

 

 

 

 

 

 

 

 

EBD_

---

Maintenance

Maintenance mode

 

Advisory

 

Swirl maintenance

No action required

 

 

Mode Exited

exited

 

(self-clear-

 

mode exited

 

 

 

 

 

 

ing)

 

 

 

 

 

 

 

 

 

 

 

 

MBD_

---

Maintenance

Maintenance due on

 

Advisory

 

Swirl active time total-

Service Component

 

 

Due - Orbiter

swirl orbiter

 

 

 

izer exceeded limit set-

 

 

 

 

 

 

 

 

ting

If necessary, reset

 

 

 

 

 

 

 

 

totalizer

 

 

 

 

 

 

 

 

 

WBD_

---

Swirl Motor Fault

Motor speed is outside

 

Alarm

 

Cable disconnected

Verify cable connec-

 

 

 

the +/- 50% tolerance

 

 

 

 

tions to swirl board,

 

 

 

range for at least 5 sec-

 

 

 

 

swirl motor cable, and

 

 

 

onds while operating

 

 

 

 

swirl orbiter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shorted motor cable

Replace swirl motor

 

 

 

 

 

 

 

(amber LED on swirl

cable (55 ft)

 

 

 

 

 

 

 

board will be on)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Orbiter bearing failure

Replace bearing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor defective

Replace swirl orbiter

 

 

 

 

 

 

 

 

 