Fluid Plate Setup Screens

There are nine fluid plate setup screens, which enable users to:

Set controls and valve commands

Set on and off delays for valves and the regula- tor

Set k-factor, pressure, and flow rate variables

Set offsets for inlet and outlet pressures

Set error types

Set variables for maintenance advisories

Define styles

Associate swirl dispenser with fluid plate

Press to scroll through the fluid plate setup

screens. Once in the desired screen, press to

access the fields to make changes. Press to exit edit mode.

NOTE: Users must be out of edit mode to scroll through the fluid plate setup screens.

Fluid Plate x, Screen 1 (Control Settings)

This screen enables users to:

Set the dispense trigger source to Gateway, Com- mand Cable, Command Cable 3x, or Combined. If it is set to Command Cable, users can enable the valves.

Set the command value source to Gateway, Com- mand Cable, or Display.

Set the Job End Timer to Timer or Gateway. If this field is set to Timer, users can set Job End Delay.

Set the Display Control Password to Enable or Dis- able. When entering maintenance mode, a pass- word prompt will appear if the Display Control Password is set to Enable and a password is set in the Advanced setup screens.

Appendix A - Advanced Display Module (ADM)

Set the Run Mode Bead Adjust to Enable or Dis- able.

NOTE: Run mode bead adjust allows a user to quickly adjust flow rate or pressure from the run screen.

Fluid Plate x, Screen 2 (Mode Settings)

This screen enables users to set valve commands. Use this screen to select a mode (pressure, bead, shot, or full open) for each valve. Users can also set the flow rate or pressure for each valve, and adjust the bead scale.

NOTE: The ability to dispense from multiple valves simultaneously is only allowed in either of the following scenarios.

Each valve is set to Pressure mode and has identical command values.