Graco 3A2098H important safety instructions Ekd, Ehd

Models: 3A2098H

1 142
Download 142 pages 28.28 Kb
Page 72
Image 72

Errors

Event

Gateway

 

Event

 

 

 

 

Code

Error No.

Event Name

Description

Event Type

 

Cause

Solution

 

 

 

 

 

 

 

 

 

 

 

Fluid Plate Events and Errors

 

 

P1C_

69

Low Pressure

Measured outlet pres-

Alarm or

 

Incorrect limit set

Verify limit is set cor-

P2C_

 

 

sure less than desired

Deviation

 

 

rectly

 

 

 

outlet pressure minus

(user select-

 

 

 

 

 

 

 

No or insufficient

Increase material flow

 

 

 

tolerance

able)

 

 

 

 

 

material flow

rate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dispense valve nee-

Dislodge and inspect

 

 

 

 

 

 

dle is stuck closed

needle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dispense valve leak-

Repair dispense valve

 

 

 

 

 

 

ing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Regulator not operat-

Repair regulator

 

 

 

 

 

 

ing correctly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pump wink passed

Increase pump pres-

 

 

 

 

 

 

through outlet

sure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Failed transducer

Check transducer;

 

 

 

 

 

 

 

replace if failed

 

 

 

 

 

 

 

 

P3C_

70

High Pressure

Measured outlet pres-

Alarm or

 

Incorrect limit set

Verify limit is set cor-

P4C_

 

 

sure greater than

Deviation

 

 

rectly

 

 

 

desired outlet pressure

(user select-

 

 

 

 

 

 

 

Dispense hose/device

Clean/replace

 

 

 

plus tolerance

able)

 

 

 

 

 

plugged

hose/device

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Failed transducer

Check transducer;

 

 

 

 

 

 

 

replace if failed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Regulator is not clos-

Repair regulator

 

 

 

 

 

 

ing completely when it

 

 

 

 

 

 

 

should

 

 

 

 

 

 

 

 

 

F1D_

71

Low Flow Rate

Measured flow rate less

Alarm or

 

Fluid supply too low to

Increase fluid supply

F2D_

 

 

than desired flow rate

Deviation

 

achieve desired flow

pressure or check for

 

 

 

minus tolerance

(user select-

 

rate

clogged filter

 

 

 

 

able)

 

 

 

 

 

 

 

 

Tip plugged

Clean/replace tip

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No air pressure to

Turn on air to solenoid

 

 

 

 

 

 

solenoid valves

valves

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No flow meter signal

Check cable and sen-

 

 

 

 

 

 

 

sor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No material supply

Replace drum or turn

 

 

 

 

 

 

 

on pumps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Incorrect flow toler-

Enter correct toler-

 

 

 

 

 

 

ance of flow error time

ance or flow error time

 

 

 

 

 

 

 

 

F3D_

72

High Flow Rate

Measured flow rate

Alarm or

 

Operating below mini-

Increase fluid pres-

F4D_

 

 

greater than desired

Deviation

 

mum regulator operat-

sure above regulator

 

 

 

flow rate plus tolerance

(user select-

 

ing pressure

minimum

 

 

 

 

able)

 

 

 

 

 

 

 

 

Regulator worn or not

Repair regulator

 

 

 

 

 

 

 

 

 

 

 

 

operating correctly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flow meter providing

Replace flow meter

 

 

 

 

 

 

false pulses

sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Incorrect flow error tol-

Enter correct toler-

 

 

 

 

 

 

erance or flow error

ance or flow error time

 

 

 

 

 

 

time

 

 

 

 

 

 

 

 

 

EKD_

73

Shot Terminated

Shot dispense cycle

Advisory

 

Job end timer was

No action required if

 

 

by Job Timer

terminated by job timer

 

 

used to stop shot dis-

timed shot is desired

 

 

 

 

 

 

pense

 

 

 

 

 

 

 

 

 

EHD_

74

Purge Timer

Purge timer expired

Advisory

 

PCF purge timer (style

Automation control

 

 

Expired

 

 

 

0) has expired

requests purge

 

 

 

 

 

 

 

 

72

3A2098H

Page 72
Image 72
Graco 3A2098H important safety instructions Ekd, Ehd