Mount Four-Valve Breakout Kit 24B693

PCF is capable of controlling up to four separate dis- pense valves from port 1 on the FCM. A four-valve breakout kit (24B693) is available to split the dispense solenoid connector (port 1 on the FCM) into four sepa- rate dispense solenoid connectors. For each additional dispense valve, order one dispense valve

solenoid (258334) and one solenoid cable (121806).

Follow this procedure if using the four-valve breakout kit.

1.Remove the existing dispense solenoid and cable from the fluid plate.

2.Install bulkhead fitting (included in the kit) into the empty hole on the fluid plate.

GCA Cable

Connection 1

Hole for bulk- head fitting

Splitter Assembly

J1

J3

 

J2 J4

FIG. 16: Mount Breakout Kit

3.Connect one end of the extension cables (included in the kit) to connection 1 on the FCM and the other end of the cable to the bulkhead fitting.

4.Connect the splitter assembly to the bulkhead fit- ting.

Installation

5.Connect the dispense valve cable(s) to the connec- tions on the splitter assembly.

 

Connects to Splitter

Cable for:

Connection Labeled:

 

 

Dispense Valve 1

J1

 

 

Dispense Valve 2

J2

 

 

Dispense Valve 3

J3

 

 

Dispense Valve 4

J4

 

 

6.Mount splitter assembly and dispense valves, and connect air lines as necessary for application.

Custom Breakout Cable

If desired, the following connector pinout information may be used to build a custom breakout cable:

Pinout of FCM Port 1

Pin 1: Dispense Solenoid 4

Pin 2: Dispense Solenoid 2

Pin 3: Voltage - (common for all solenoids)

Pin 4: Dispense Solenoid 1

Pin 5: Dispense Solenoid 3

Dispense solenoid outputs are 24 Vdc. Dispense sole- noid outputs are capable of sourcing up to 0.5A each (maximum 12W coil).

3A2098H

25

Page 25
Image 25
Graco 3A2098H Mount Four-Valve Breakout Kit 24B693, Custom Breakout Cable, Connects to Splitter