Upgrade Fluid Control Module (FCM) Software

NOTE: The FCM connection is temporarily disabled during the use of the upgrade token.

1.Turn off power to the system.

2.Remove access cover then remove key token (do not discard token).

Access

Cover

TI12334A

FIG. 47: Remove Access Cover

3. Insert and press software token firmly into slot.

NOTE: There is no preferred orientation of token.

4.Turn on power to the system. The red indicator light (CK) will flash until new software is completely loaded.

CK

TI12335A

Token

FIG. 48: Insert Token

5.After the red indicator light shuts off, turn off power to the system.

6.Remove software token.

Maintenance

7. Reinstall key token, and replace access cover.

Air Filter Maintenance

To prevent filter element damage, replace air filter every two years or when pressure drop becomes 100 kPa (1.0 bar, 14.5 psi) or greater; which ever occurs first.

Replacement Air Filters for Dual Filter

Assembly (234967)

Part

Description

 

 

123091

5 micron air filter

 

 

123092

0.3 micron air filter

 

 

Swirl Dispensers

See manual 309403 for maintenance schedule.