Repair

Repair

Fluid Plate Assembly

 

 

Repair Flow Meter

 

 

 

 

 

 

 

 

 

For complete flow meter (129) repair instructions refer to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the maintenance and repair section of manual 309834.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This section describes how to remove and replace com- ponents on the fluid plate assembly.

Prepare Fluid Plate Assembly for Repair

1.Disconnect the CAN cable from the fluid plate.

2.Perform Pressure Relief Procedure on page 57.

3.Remove the fluid plate assembly shroud. See Fluid Plate Assembly Parts, page 94.

103

124

129

125, 126, 127

FIG. 49: Fluid Plate Assembly

Remove Flow Meter from Mounting Plate

1.Prepare Fluid Plate Assembly for Repair, page 80.

2.Disconnect the flow meter cable (131) from the flow meter sensor. See FIG. 49.

3.Disconnect the material hose.

4.Disconnect the swivel fitting (109) from the regula- tor.

5.Loosen the four screws (127) and washers (125, 126); remove the bracket (124) and flow meter (129).

6.The flow meter weighs approximately 15 lbs. (6.75 kg). Carefully lift it off the mounting plate (101).

101

108

131 109

r_pf0000_313377_18a

80

3A2098H

Page 80
Image 80
Graco 3A2098H Fluid Plate Assembly, Repair Flow Meter, Remove Flow Meter from Mounting Plate