Errors

Event

Gateway

 

Event

 

 

 

Code

Error No.

Event Name

Description

Event Type

Cause

Solution

 

 

 

 

 

 

 

 

 

 

Control Center Events and Errors

 

EBUX

---

Download to

Download to the USB is

Advisory

---

No action necessary

 

 

USB Complete

complete

(self-clearing)

 

 

 

 

 

 

 

 

 

WSU0

---

USB configura-

USB configuration error

Advisory

USB configuration

Reinstall system soft-

 

 

tion error

 

 

invalid or not present

ware on display

 

 

 

 

 

 

 

WNC0

32

ADM Key Token

Missing or invalid key

Alarm

An ADM key token is

Verify the key token is

 

 

Error

token

 

required to run the

installed

 

 

 

 

 

system

 

 

 

 

 

 

Verify the key token

 

 

 

 

 

 

 

 

 

 

 

 

part number is correct

 

 

 

 

 

 

for the PCF ADM

 

 

 

 

 

 

 

WNG0

---

Gateway Map

Missing or invalid map

Advisory

Missing or invalid

Install PCF map in

 

 

Error

 

 

Gateway map

Gateway

 

 

 

 

 

 

 

CBG0

---

Gateway Reset

Gateway reset

Advisory

Gateway setting(s)

Wait for reset to com-

 

 

 

 

(self-clearing)

changed

plete before attempt-

 

 

 

 

 

 

ing automation control

 

 

 

 

 

 

 

WMG0

---

Gateway Error

Gateway error

Alarm

---

---

 

 

Detected

detected; includes any

 

 

 

 

 

 

error not covered by

 

 

 

 

 

 

another more specific

 

 

 

 

 

 

error

 

 

 

 

 

 

 

 

 

 

CBD_

---

Fluid Plate Com-

Fluid Plate Communi-

Alarm

The ADM lost commu-

Restore communica-

 

 

munication Error

cation Error with ADM

 

nications with the

tion.

 

 

 

 

 

FCM.

 

 

 

 

 

 

 

 

CCG_

---

Fieldbus Com-

Fieldbus Communica-

Alarm

The automation gate-

Restore communica-

 

 

munication Error

tion Error

 

way lost communica-

tions.

 

 

 

 

 

tion with the

 

 

 

 

 

 

automation controller.

 

 

 

 

 

 

 

 

Fluid Plate Events and Errors

Event

Gateway

 

Event

 

 

 

 

Code

Error No.

Event Name

Description

Event Type

 

Cause

Solution

 

 

 

 

 

 

 

 

 

 

 

Fluid Plate Events and Errors

 

 

CAC_

---

CGM Communi-

Communication lost

Advisory

 

Fluid Plate and CGM

Reconnect or replace

 

 

cation Error

between CGM and

 

 

are no longer commu-

CAN cable

 

 

 

Fluid Plate

 

 

nicating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CGM is not functioning

Replace the CGM if the

 

 

 

 

 

 

 

red status LED is solid

 

 

 

 

 

 

 

 

CAD_

---

Fluid Plate Com-

FCM lost communica-

Alarm

 

ADM is not communi-

Reconnect or replace

 

 

munication Error

tion with the ADM

 

 

cating

CAN cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ADM is not functioning

Replace FCM if red

 

 

 

 

 

 

 

status LED is solid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ADM does not contain

Verify intended ADM

 

 

 

 

 

 

appropriate key token

key token is properly

 

 

 

 

 

 

 

inserted

 

 

 

 

 

 

 

 

B7C_

30

Style Out of

Style is out of range

Alarm

 

Style requested by

Use a style number

 

 

Range

 

 

 

automation controller

that is in range

 

 

 

 

 

 

exceeds number of

 

 

 

 

 

 

 

Increase number of

 

 

 

 

 

 

styles available on the

 

 

 

 

 

 

styles in PCF; pur-

 

 

 

 

 

 

fluid plate

chase accessory key

 

 

 

 

 

 

 

 

 

 

 

 

 

 

token

 

 

 

 

 

 

 

 

68

3A2098H

Page 68
Image 68
Graco 3A2098H important safety instructions Fluid Plate Events and Errors