Graco 3A2098H important safety instructions Refer to Fluid Plate, Assembly Overview

Models: 3A2098H

1 142
Download 142 pages 28.28 Kb
Page 73
Image 73

 

 

 

 

 

 

 

Errors

 

 

 

 

 

 

 

 

Event

Gateway

 

Event

 

 

 

 

Code

Error No.

Event Name

Description

Event Type

 

Cause

Solution

 

 

 

 

 

 

 

 

 

 

 

Fluid Plate Events and Errors

 

 

EAC_

75

Maintenance

Maintenance mode

Advisory

 

Entered maintenance

No action required

 

 

Mode Entered

entered

(self-clearing)

 

dispense mode

 

 

 

 

 

 

 

 

 

EBC_

76

Maintenance

Maintenance mode

Advisory

 

Exited maintenance

No action required

 

 

Mode Exited

exited

(self-clearing)

 

dispense mode

 

 

 

 

 

 

 

 

 

MHD_

77

Maintenance

Maintenance due for

Advisory

 

Totalizer exceeded

Service component

 

 

Due - Regulator

regulator

 

 

limit setting

If necessary, reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

totalizer

 

 

 

 

 

 

 

 

MFD_

78

Maintenance

Maintenance due for

Advisory

 

Totalizer exceeded

Service component

 

 

Due - Flow Meter

flow meter

 

 

limit setting

If necessary, reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

totalizer

 

 

 

 

 

 

 

 

MED_

79

Maintenance

Maintenance due for

Advisory

 

Totalizer exceeded

Service component

 

 

Due - V/P

Voltage to Pressure

 

 

limit setting

If necessary, reset

 

 

 

Transducer

 

 

 

 

 

 

 

 

 

 

totalizer

 

 

 

 

 

 

 

 

MCD_

80

Maintenance

Maintenance due for

Advisory

 

Totalizer exceeded

Service component

 

 

Due - Supply

supply system

 

 

limit setting

If necessary, reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

totalizer

 

 

 

 

 

 

 

 

MD1_

81

Maintenance

Maintenance due for

Advisory

 

Totalizer exceeded

Service component

 

 

Due - Valve 1

valve 1

 

 

limit setting

If necessary, reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

totalizer

 

 

 

 

 

 

 

 

MD2_

82

Maintenance

Maintenance due for

Advisory

 

Totalizer exceeded

Service component

 

 

Due - Valve 2

valve 2

 

 

limit setting

If necessary, reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

totalizer

 

 

 

 

 

 

 

 

MD3_

83

Maintenance

Maintenance due for

Advisory

 

Totalizer exceeded

Service component

 

 

Due - Valve 3

valve 3

 

 

limit setting

If necessary, reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

totalizer

 

 

 

 

 

 

 

 

MD4_

84

Maintenance

Maintenance due for

Advisory

 

Totalizer exceeded

Service component

 

 

Due - Valve 4

valve 4

 

 

limit setting

If necessary, reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

totalizer

 

 

 

 

 

 

 

 

CCD_

85

Duplicate Module

Duplicate Fluid Control

Alarm

 

Two or more FCMs

Verify that all FCMs

 

 

 

Module Detected

 

 

have the same rotary

have proper rotary

 

 

 

 

 

 

switch setting

switch settings. Reset

 

 

 

 

 

 

 

module after changing

 

 

 

 

 

 

 

rotary switch setting.

 

 

 

 

 

 

 

Refer to Fluid Plate

 

 

 

 

 

 

 

Assembly Overview

 

 

 

 

 

 

 

section, page 14

 

 

 

 

 

 

 

 

EAD_

86

Swirl Mainte-

Swirl maintenance

Advisory

 

Swirl zone that is

No action required

 

 

nance Mode

mode entered

(self-clearing)

 

associated with this

 

 

 

Entered

 

 

 

fluid plate entered

 

 

 

 

 

 

 

maintenance mode

 

 

 

 

 

 

 

 

 

WFC_

87

Shot No-Flow

No flow detected for

Alarm

 

Dispense valve not

Check dispense valve

 

 

Timeout

five seconds on valve

 

 

operating properly

for correct operation

 

 

 

activated in shot mode

 

 

 

and/or clogging

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fluid leak

Check fluid connec-

 

 

 

 

 

 

 

tions

 

 

 

 

 

 

 

 

3A2098H

73

Page 73
Image 73
Graco 3A2098H important safety instructions Refer to Fluid Plate, Assembly Overview