Fluid Plate x, Screen 2 (Control Center)

NOTE: Users must be out of maintenance mode in Fluid Plate x, screen 1 in order to scroll to this screen.

NOTE: The term “Robot” on this screen refers to the automation controller.

This screen enables users to view and monitor the cur- rent status of the “robot” outputs and inputs. An X is dis- played in the applicable check box when:

Using a style strobe

The dispense is complete

A dispense trigger occurs

The dispenser (fluid plate) is ready

The dispense is in process

There are no alarms or errors

The dispense volume is correct

This screen also displays the current dispense style, command voltage, Gateway error number/code, and the volume dispensed.

Appendix A - Advanced Display Module (ADM)

Fluid Plate x, Screen 3 (Maintenance Totalizers)

This screen enables users to view the maintenance totalizers for each system component and the limits set that will trigger a maintenance advisory.

Maintenance totalizers keep track of the total volume (or hours) that each system component has been running. If the totalizer value exceeds the set limit, the totalizer value will turn red and a maintenance advisory is issued.

The limits are set in the Fluid Plate x, Screen 7 (Main- tenance Advisory Limits), page 108, for the air supply, voltage to pressure (V/P) transducer, fluid regulator, flow meter, and all four valves.

NOTE: If a flow meter is not included in the system, this screen shows hours instead of volume and the flow meter entry is grayed out.