USB Data

All files downloaded from the USB are put in a DOWN- LOAD folder on the drive. For example: “E:\GRACO\12345678\DOWNLOAD\”

The 8-digit numeric folder name matches the 8-digit ADM serial number. When downloading from multiple ADMs, there will be one sub-folder in the GRACO folder for each ADM.

USB Logs

FIG. 39: ADM USB Port

During operation, PCF stores system and performance related information to memory in the form of log files. PCF maintains three types of log files: a job log, an event log, and dispense data logs. Follow the Down- load Procedure, page 61, to retrieve log files.

Event Log

The event log file name is 1-EVENT.CSV and is stored in the DOWNLOAD folder.

The event log maintains a record of the last 1,000 events. Each event record in the log file contains the date and time the event occurred, the event type, event code, and event description.

Job Log

The job log file name is 2-JOB.CSV and is stored in the DOWNLOAD folder.

The job log maintains a record of the last 10,000 jobs. At the completion of each job the following data is stored in the log file:

Job completion date

Job completion time

Job number (sequential number)

Dispenser (Fluid Plate) Number

Style number

USB Data

Target volume (in the units shown in the volume units column)

Requested volume (in the units shown in the volume units column)

Actual dispensed volume (in the units shown in the volume units column)

Volume units

Error percentage between actual dispensed vol- ume and requested volume (maximum of 100%)

Minimum inlet pressure during job (measured in bar, heated systems will always read 0)

Average inlet pressure during job (measured in bar, heated systems will always read 0)

Maximum inlet pressure during job (measured in bar, heated systems will always read 0)

Minimum outlet pressure during job (measured in bar)

Average outlet pressure during job (measured in bar)

Maximum outlet pressure during job (measured in bar)

Minimum flow rate during job (measured in cc/min, systems with no flow meter will read 0)

Average flow rate during job (measured in cc/min, systems with no flow meter will read 0)

Maximum flow rate during job (measured in cc/min, systems with no flow meter will read 0)

Elapsed time (mS)

Dispense Data Log

The dispense data log file name is 3-DATAx.CSV and is stored in the DOWNLOAD folder. There is one dispense data log file for each installed fluid plate, so there can be up to four data logs.

The dispense data log maintains a record of system inlet pressure (heated systems will always read 0), system outlet pressure, system flow rate (systems without flow meters will always read 0), and active dispense valves. This data is recorded at one second intervals when a job cycle is in process. Each dispense data log is capable of storing up to two hours of data.

3A2098H

59

Page 59
Image 59
Graco 3A2098H important safety instructions USB Data, USB Logs, Event Log, Job Log, Dispense Data Log