Graco 3A2098H important safety instructions Wfd, Wfg, Ejd, Wxd

Models: 3A2098H

1 142
Download 142 pages 28.28 Kb
Page 71
Image 71

 

 

 

 

 

 

 

Errors

 

 

 

 

 

 

 

 

Event

Gateway

 

Event

 

 

 

 

Code

Error No.

Event Name

Description

Event Type

 

Cause

Solution

 

 

 

 

 

 

 

 

 

 

 

Fluid Plate Events and Errors

 

 

V2D_

62

Low Analog

Command cable analog

Deviation

 

Bad or loose com-

Check command cable

 

 

 

command dropped

 

 

mand cable connec-

and connection

 

 

 

below minimum value

 

 

tion

 

 

 

 

of 1 V while dispensing

 

 

 

 

 

 

 

 

 

Entered command

Enter correct com-

 

 

 

 

 

 

 

 

 

 

 

 

mode incorrectly

mand code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Automation program

Verify correct automa-

 

 

 

 

 

 

error

tion program

 

 

 

 

 

 

 

 

WFD_

63

Flow Meter

Operating mode

Alarm or

 

Selected valve mode

Check valve mode set-

WFG_

 

Required

requires flow meter.

Advisory

 

settings require flow

tings

 

 

 

Advisory is issued if

(self-clearing)

 

meter

Purchase meter

 

 

 

fluid plate settings

 

 

 

 

 

 

require a flow meter but

 

 

 

enabled token for FCM

 

 

 

meter is not present.

 

 

 

and install flow meter

 

 

 

Alarm is issued if dis-

 

 

FCM key token miss-

Check for FCM key

 

 

 

pense is attempted in

 

 

ing or invalid

token error

 

 

 

mode that requires a

 

 

 

 

 

 

 

flow meter but meter is

 

 

 

 

 

 

 

not present.

 

 

 

 

 

 

 

 

 

 

 

 

EJD_

64

Job Cycle Time

Job cycle time out

Alarm

 

Automation signals did

Check automation pro-

 

 

Out

 

 

 

not properly end job

gramming per job oper-

 

 

 

 

 

 

cycle

ating instruction

 

 

 

 

 

 

 

 

WXD_

65

Fluid Plate Error

Fluid plate error

Alarm

 

Analog voltage applied

Limit signal on pin 1 of

 

 

Detected

detected; includes any

 

 

to pin 1 of the com-

command cable to the

 

 

 

error not covered by

 

 

mand cable exceeds

range of 0-10 Vdc.

 

 

 

another more specific

 

 

10 Vdc.

 

 

 

 

error

 

 

 

 

 

 

 

 

 

Failed FCM

Replace FCM if neces-

 

 

 

 

 

 

 

 

 

 

 

 

 

sary

 

 

 

 

 

 

 

 

P3F_

66

Maximum Inlet

Inlet pressure to regula-

Alarm or

 

Incorrect set limit

Verify limit is set cor-

P4F_

 

Pressure

tor is above upper limit

Deviation

 

 

rectly

 

 

 

set for operation

(user select-

 

 

 

 

 

 

 

Material supply pres-

Decrease material

 

 

 

 

able)

 

 

 

 

 

 

sure is too high

supply pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Failed transducer

Check transducer;

 

 

 

 

 

 

 

replace if necessary

 

 

 

 

 

 

 

 

P3D_

67

Maximum Outlet

Outlet pressure of regu-

Alarm or

 

Incorrect set limit

Verify limit is set cor-

P4D_

 

Pressure

lator is above upper

Deviation

 

 

rectly

 

 

 

limit set for operation

(user select-

 

 

 

 

 

 

 

Material supply pres-

Decrease material

 

 

 

 

able)

 

 

 

 

 

 

sure is too high

supply pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Failed transducer

Check transducer;

 

 

 

 

 

 

 

replace if necessary

 

 

 

 

 

 

 

 

P1F_

68

Minimum Inlet

Inlet pressure to regula-

Alarm or

 

Incorrect set limit

Verify limit is set cor-

P2F_

 

Pressure

tor is below lower limit

Deviation

 

 

rectly

 

 

 

set for operation

(user select-

 

 

 

 

 

 

 

Material supply pres-

Increase crease mate-

 

 

 

 

able)

 

 

 

 

 

 

sure is too low

rial supply pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Failed transducer

Check transducer;

 

 

 

 

 

 

 

replace if necessary

 

 

 

 

 

 

 

 

3A2098H

71

Page 71
Image 71
Graco 3A2098H important safety instructions Wfd, Wfg, Ejd, Wxd