Errors

Event and Error Codes and Troubleshooting

Error codes are stored in the events log and are displayed on the error report screens. Gateway error numbers are reported over the Gateway interface.

Error codes shown as XYZ_ represent error codes XYZ1, XYZ2, XYZ3, XYZ4, where the last digit represents the number of the fluid plate to which the error applies. Error codes in the following table are sorted by gateway error number, then by event code.

System Events and Errors

Event

Gateway

 

Event

 

 

 

Code

Error No.

Event Name

Description

Event Type

Cause

Solution

 

 

 

 

 

 

 

 

 

 

System Events and Errors

 

 

---

0

No Active Errors

No errors

---

---

No action necessary

 

 

 

 

 

 

 

EC0X

---

Setup Values

Setup change notifica-

Record only

A setup value was

No action necessary if

 

 

Changed

tion

 

changed on the dis-

changes were desired

 

 

 

 

 

play

 

 

 

 

 

 

 

 

EL0X

---

Power Up

Control box power up

Record only

---

No action necessary

 

 

 

 

 

 

 

EM0X

---

Power Down

Control box power

Record only

---

---

 

 

 

down

 

 

 

 

 

 

 

 

 

 

Control Center Events and Errors

Event

Gateway

 

Event

 

 

 

Code

Error No.

Event Name

Description

Event Type

Cause

Solution

 

 

 

 

 

 

 

 

 

 

Control Center Events and Errors

 

EVUX

---

USB Disabled

USB download

Advisory

Transfers are disabled

Clears when drive is

 

 

 

attempted, however,

(self-clearing)

in Advanced Setup

removed.

 

 

 

USB activity is dis-

 

screen 2.

 

 

 

 

abled.

 

 

 

 

 

 

 

 

 

 

MMUX

---

USB Log 90%

One or more USB log is

Advisory

Data in the jobs or

Download the data or

 

 

Full

90% full.

 

events log has not

disable USB errors.

 

 

 

 

 

been downloaded

 

 

 

 

 

 

recently and logs are

 

 

 

 

 

 

nearly full.

 

 

 

 

 

 

 

 

V1G0

---

DGM Unpowered

The Discrete Gateway

Advisory

24 Vdc has not been

Connect power accord-

 

 

 

Module does not have

 

connected to the

ing to Appendix B -

 

 

 

logic power supplied to

 

power pins.

Discrete Gateway

 

 

 

it.

 

 

Module (DGM) Con-

 

 

 

 

 

 

nection Details on

 

 

 

 

 

 

page 115.

 

 

 

 

 

 

 

WSG0

---

Gateway Setup

System settings are

Advisory

Fluid plate 1 is not

Install fluid plate 1,

 

 

Error

incompatible with Dis-

 

installed. Or Fluid

uninstall fluid plates 3

 

 

 

crete Gateway Module.

 

plate 3 or fluid plate 4

and 4.

 

 

 

 

 

is installed.

 

 

 

 

 

 

 

 

 

 

 

 

 

Swirl 1 is not installed.

Install Swirl 1, unin-

 

 

 

 

 

Or Swirl 3 or Swirl 4 is

stall swirls 3 and 4.

 

 

 

 

 

installed.

 

 

 

 

 

 

 

 

EAUX

---

Download to

Information is currently

Advisory

---

No action necessary

 

 

USB in Process

being downloaded to

(self-clearing)

 

 

 

 

 

USB

 

 

 

 

 

 

 

 

 

 

3A2098H

67

Page 67
Image 67
Graco 3A2098H Event and Error Codes and Troubleshooting, System Events and Errors, Control Center Events and Errors