Install Flow Meter on Mounting Plate

1.Rest the flow meter (129) and bracket (124) on the fluid plate while threading the swivel fitting (109) onto the regulator material inlet. See FIG. 49.

2.Tighten the swivel fitting to the regulator material inlet.

3.Tighten the four screws (127) and washers (125, 126) to hold the bracket and flow meter in place.

Repair

4.Remove the dispense valve solenoid (132) and replace it with a new solenoid.

137

132

118

126

127

129

124

108

109

125 r_pf0000_313377_34a

FIG. 50

4.Check that the flow meter and regulator (108) are still aligned.

5.Connect the material hose.

6.Connect the flow meter cable (131).

Replace Solenoid

1.Prepare Fluid Plate Assembly for Repair, page 80.

2.Disconnect FCM cable and all three air tubes.

3.Remove both screws (137) from transducer bracket (118).

r_pf0000_313377_33a

FIG. 51

5.Secure the new solenoid to the bracket with screws.

6.Reconnect the FCM cable and all three air tubes.

Replace Voltage to Pressure (V/P) Transducer

1.Prepare Fluid Plate Assembly for Repair, page 80.

2.Disconnect the FCM cable and both air tubes.

3.Remove both transducer screws (122) from trans- ducer bracket (118).

4.Remove the V/P transducer (121) and replace it with a new V/P transducer.

118

121

122

r_pf0000_313377_31a

FIG. 52

3A2098H

81

Page 81
Image 81
Graco 3A2098H Install Flow Meter on Mounting Plate, Replace Solenoid, Replace Voltage to Pressure V/P Transducer