Errors

 

 

 

 

 

 

 

 

Event

Gateway

 

Event

 

 

 

 

Code

Error No.

Event Name

Description

Event Type

 

Cause

Solution

 

 

 

 

 

 

 

 

 

 

 

Fluid Plate Events and Errors

 

 

B30_

31

High Material

Material dispensed dur-

Alarm or

 

PCF regulator is not

Check regulator and

B40_

 

 

ing last dispense cycle

Deviation

 

regulating correctly

repair if necessary

 

 

 

was above amount

(user select-

 

 

 

 

 

 

 

Incorrect style target

Enter correct values or

 

 

 

requested plus the

able)

 

 

 

 

 

volume or tolerance

set tolerance to 0% to

 

 

 

allowed tolerance

 

 

 

 

 

 

 

 

disable error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B10_

32

Low Material

Material dispensed dur-

Alarm or

 

Partially plugged tip or

Clean tip and/or supply

B20_

 

 

ing last dispense cycle

Deviation

 

supply system

system

 

 

 

below amount

(user select-

 

 

 

 

 

 

 

Insufficient flow to

Increase flow rate to

 

 

 

requested minus the

able)

 

 

 

 

 

PCF regulator inlet

regulator inlet

 

 

 

allowed tolerance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PCF regulator is not

Incorrect style target

 

 

 

 

 

 

 

 

 

 

 

 

regulating correctly

volume or tolerance

 

 

 

 

 

 

Check regulator;

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

repair if necessary

 

 

 

 

 

 

 

 

 

B1C_

33

Low Computed

Requested volume/

Alarm or

 

Entered process target

Enter correct process

B2C_

 

Target

mass differs from

Deviation

 

incorrectly

target

 

 

 

entered process target

(user select-

 

 

 

 

 

 

 

Entered tolerance

Enter correct tolerance

 

 

 

by more than entered

able)

 

 

 

 

 

incorrectly

 

 

 

 

tolerance for style

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Requested volume

Check automation pro-

 

 

 

requested

 

 

 

 

 

 

 

incorrectly

gram

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Automation problem

Verify automation is

 

 

 

 

 

 

 

correct

 

 

 

 

 

 

 

 

B3C_

34

High Computed

Requested volume/

Alarm or

 

Entered process target

Enter correct process

B4C_

 

Target

mass differs from

Deviation

 

incorrectly

target

 

 

 

entered process target

(user select-

 

 

 

 

 

 

 

Entered tolerance

Enter correct tolerance

 

 

 

by more than entered

able)

 

 

 

 

 

incorrectly

 

 

 

 

tolerance for style

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Requested volume

Check automation pro-

 

 

 

requested

 

 

 

 

 

 

 

incorrectly

gram

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Automation problem

Verify automation is

 

 

 

 

 

 

 

correct

 

 

 

 

 

 

 

 

WND_

51

Fluid Plate Key

Missing or invalid key

Alarm

 

FCM key token is

Verify FCM key token

 

 

Token Error

token

 

 

required to run system

is installed

 

 

 

 

 

 

 

Verify FCM key token

 

 

 

 

 

 

 

is correct part number

 

 

 

 

 

 

 

 

P6D_

52

Outlet Pressure

Outlet pressure trans-

Alarm

 

Problem detected with

Verify outlet pressure

 

 

Transducer Error

ducer error

 

 

outlet pressure trans-

transducer is installed

 

 

 

 

 

 

ducer

and/or connected cor-

 

 

 

 

 

 

 

rectly

 

 

 

 

 

 

 

Replace if necessary

 

 

 

 

 

 

 

 

P6F_

53

Inlet Pressure

Inlet pressure trans-

Advisory

 

Problem detected with

Verify inlet pressure

 

 

Transducer Error

ducer error

 

 

inlet pressure trans-

transducer is installed

 

 

 

 

 

 

ducer

and/or connected cor-

 

 

 

 

 

 

 

rectly

 

 

 

 

 

 

 

Replace if necessary

 

 

 

 

 

 

 

 

F6D_

54

Flow Meter Error

Flow Meter error

Alarm

 

Problem detected with

Verify flow meter is

 

 

 

 

 

 

flow meter

installed and/or con-

 

 

 

 

 

 

 

nected correctly

 

 

 

 

 

 

 

Replace if necessary

 

 

 

 

 

 

 

 

3A2098H

69

Page 69
Image 69
Graco 3A2098H important safety instructions Wnd