Graco 3A2098H Swirl Commands, Output Bits Read or 264-275 Description Gateway Units Write

Models: 3A2098H

1 142
Download 142 pages 28.28 Kb
Page 136
Image 136

Appendix C - Communications Gateway Module (CGM) Connection Details

Output

 

Units

 

Bits

 

*See Units

Read or

256-267

Description

Definitions, page 137

Write

 

 

 

 

0x29E

Pressure Units

Pressure Units Enu-

Read /

 

 

meration

Write

 

 

 

 

0x29F

Rate Units

Rate Units Enumera-

Read /

 

 

tion

Write

 

 

 

 

0x2A0

Maintenance

Volume Units Enumer-

Read /

 

Volume Units

ation

Write

 

 

 

 

0x2A1

Maintenance

Mass Units Enumera-

Read /

 

Mass Units

tion

Write

 

 

 

 

0x2A2

Maintenance

Mass Units Enumera-

Read /

 

Time Units

tion

Write

 

 

 

 

0x2AD

Valve 1 Swirl

Swirl Enumeration

Read /

 

Association

 

Write

 

(Swirl Zone)

 

 

 

 

 

 

0x2AE

Valve 2 Swirl

Swirl Enumeration

Read /

 

Association

 

Write

 

(Swirl Zone)

 

 

 

 

 

 

0x2AF

Valve 3 Swirl

Swirl Enumeration

Read /

 

Association

 

Write

 

(Swirl Zone)

 

 

 

 

 

 

0x2B0

Valve 4 Swirl

Swirl Enumeration

Read /

 

Association

 

Write

 

(Swirl Zone)

 

 

 

 

 

 

0x2B5

End Job On

Boolean

Read /

 

Alarm

 

Write

 

 

 

 

0x3FB

Style Bits

###

Read /

 

 

 

Write

 

 

 

 

0x115

Command

uint12

Read /

 

Value

 

Write

 

 

 

 

0x116

Error Reset /

Dispense Control 2 Bit-

Read /

 

Remote Start

field

Write

 

 

 

 

0x118

Disable Dis-

Boolean

Read /

 

pensing

 

Write

 

 

 

 

0x3FF

Dispense Con-

Dispense Control 1 Bit-

Read /

 

trol

field

Write

 

 

 

 

0x0FB

Inlet Pressure

Pressure: #### (psi);

Read Only

 

 

###.# (bar); ##.##

 

 

 

(Mpa)

 

 

 

 

 

0x0FC

Outlet Pres-

Pressure: #### (psi);

Read Only

 

sure

###.# (bar); ##.##

 

 

 

(Mpa)

 

 

 

 

 

0x0DC

Pressure Com-

Pressure: #### (psi);

Read Only

 

mand

###.# (bar); ##.##

 

 

 

(Mpa)

 

 

 

 

 

0x403

Flowrate Com-

##### cc/min

Read Only

 

mand

 

 

 

 

 

 

0x404

Flowrate

##### cc/min

Read Only

 

Actual

 

 

 

 

 

 

0x406

Fluid Plate Sta-

Fluid Plate Status 0

Read Only

 

tus 0

bitfield

 

 

 

 

 

0x409

Fluid Plate

Gateway Error Number

Read Only

 

Faults

 

 

 

 

 

 

Output

 

Units

 

Bits

 

*See Units

Read or

256-267

Description

Definitions, page 137

Write

 

 

 

 

0x0FF

Fluid Plate Dis-

#####.# (cc)

Read Only

 

pensed Vol-

 

 

 

ume

 

 

 

 

 

 

0x0DB

Active Fault

Fault Error Code

Read Only

 

Error Code

 

 

 

 

 

 

0x0F8

Fluid Plate Sta-

Fluid Plate Status bit-

Read Only

 

tus Bits

field

 

 

 

 

 

0x0FE

Requested Vol-

#####.# (cc)

Read Only

 

ume

 

 

 

 

 

 

*Maintenance dispensed volume/time can only be set to 0.

Swirl Commands

Output

 

 

 

Bits

 

 

Read or

264-275

Description

Gateway Units

Write

 

 

 

 

0x004

Software Part

STR_3_0

Read Only

 

Number

 

 

 

 

 

 

0x005

Software Part

STR_7_4

Read Only

 

Number

 

 

 

 

 

 

0x006

Software Part

STR_11_8

Read Only

 

Number

 

 

 

 

 

 

0x007

Software Part

STR_15_12

Read Only

 

Number

 

 

 

 

 

 

0x00B

Software Version

Version

Read Only

 

 

 

 

0x400

Swirl Speed

Speed Source

Read /

 

Source

Enumeration

Write

 

 

 

 

0x401

Swirl Fixed Speed

##### (RPM)

Read /

 

 

 

Write

 

 

 

 

0x403

Swirl Speed Scal-

### (percent)

Read /

 

ing

 

Write

 

 

 

 

0x404

Swirl Maintenance

###### (hours)

Read /

 

Time Advisory

 

Write

 

Limit

 

 

 

 

 

 

0x3FF

Swirl - Actual Run

###### (hours)

Read /

 

Time

 

Write

 

 

 

 

0x2FC

Swirl Status Bits 1

Swirl Status Bit-

Read Only

 

 

field 1

 

 

 

 

 

0x4FE

Swirl Actual Speed

##### (RPM)

Read Only

 

 

 

 

0x500

Swirl Control

Swirl Control

Read /

 

 

Enumeration

Write

 

 

 

 

0x501

Swirl Requested

uint12

Read /

 

Speed

 

Write

 

 

 

 

136

3A2098H

Page 136
Image 136
Graco 3A2098H important safety instructions Swirl Commands, Output Bits Read or 264-275 Description Gateway Units Write