Appendix C - Communications Gateway Module (CGM) Connection Details

Output

 

Units

 

Bits

 

*See Units

Read or

256-267

Description

Definitions, page 137

Write

 

 

 

 

0x007

Software Part

STR_15_12

Read Only

 

Number

 

 

 

 

 

 

0x008

Software Ver-

Version

Read Only

 

sion

 

 

 

 

 

 

0x0DD

Maintenance

Maintenance Units

Read Only

 

Units Type

Enumeration

 

 

 

 

 

0x0DF

Enabled Styles

###

Read Only

 

 

 

 

0x203

Purge Period

#### (minutes)

Read /

 

 

 

Write

 

 

 

 

0x204

Dispense Trig-

Dispense Trigger

Read /

 

ger Source

Source Enumeration

Write

 

 

 

 

0x208

Command

Command Value

Read /

 

Value Source

Source Enumeration

Write

 

 

 

 

0x20F

Bead Scale

### (percent)

Read /

 

 

 

Write

 

 

 

 

0x210

Job End Mode

Job End Mode Enu-

Read /

 

 

meration

Write

 

 

 

 

0x211

Job End Delay

Integer (Seconds)

Read /

 

Time

 

Write

 

 

 

 

0x2B5

End Job On

Boolean

 

 

Alarm

 

 

 

 

 

 

0x212

Valve 1 Enable

Boolean

Read /

 

 

 

Write

 

 

 

 

0x213

Valve 2 Enable

Boolean

Read /

 

 

 

Write

 

 

 

 

0x214

Valve 3 Enable

Boolean

Read /

 

 

 

Write

 

 

 

 

0x215

Valve 4 Enable

Boolean

Read /

 

 

 

Write

 

 

 

 

0x216

Regulator On

### (mS)

Read /

 

Delay

 

Write

 

 

 

 

0x217

Regulator Off

### (mS)

Read /

 

Delay

 

Write

 

 

 

 

0x218

Valve 1 On

### (mS)

Read /

 

Delay

 

Write

 

 

 

 

0x219

Valve 2 On

### (mS)

Read /

 

Delay

 

Write

 

 

 

 

0x21A

Valve 3 On

### (mS)

Read /

 

Delay

 

Write

 

 

 

 

0x21B

Valve 4 On

### (mS)

Read /

 

Delay

 

Write

 

 

 

 

0x21C

Valve 1 Off

### (mS)

Read /

 

Delay

 

Write

 

 

 

 

0x21D

Valve 2 Off

### (mS)

Read /

 

Delay

 

Write

 

 

 

 

0x21E

Valve 3 Off

### (mS)

Read /

 

Delay

 

Write

 

 

 

 

0x21F

Valve 4 Off

### (mS)

Read /

 

Delay

 

Write

 

 

 

 

0x230

Flow Meter

Flow Meter Type Enu-

Read /

 

Type

meration

Write

 

 

 

 

Output

 

Units

 

Bits

 

*See Units

Read or

256-267

Description

Definitions, page 137

Write

 

 

 

 

0x231

Flow Meter

##### (pulses/Liter,

Read /

 

K-Factor

pulses/kg)

Write

 

 

 

 

0x23C

Outlet Pres-

sint32; #### (psi);

Read /

 

sure Sensor

###.# (bar); ##.##

Write

 

User Offset

(Mpa)

 

 

 

 

 

0x23D

Inlet Pressure

sint32; #### (psi);

Read /

 

Sensor User

###.# (bar); ##.##

Write

 

Offset

(Mpa)

 

 

 

 

 

0x241

Maximum Out-

uint32; #### (psi);

Read /

 

let Pressure

###.# (bar); ##.##

Write

 

 

(Mpa)

 

 

 

 

 

0x244

Minimum Inlet

uint32; #### (psi);

Read /

 

Pressure

###.# (bar); ##.##

Write

 

 

(Mpa)

 

 

 

 

 

0x245

Maximum Inlet

uint32; #### (psi);

Read /

 

Pressure

###.# (bar); ##.##

Write

 

 

(Mpa)

 

 

 

 

 

0x248

Pressure Kp

####.##

Read /

 

 

 

Write

 

 

 

 

0x249

Pressure Ki

####.##

Read /

 

 

 

Write

 

 

 

 

0x247

Pressure Kd

####.##

Read /

 

 

 

Write

 

 

 

 

0x254

Bead Kp

####.##

Read /

 

 

 

Write

 

 

 

 

0x255

Bead Ki

####.##

Read /

 

 

 

Write

 

 

 

 

0x260

Regulator Time

###### (hours)

Read /

 

Advisory Limit

 

Write

 

 

 

 

0x262

Regulator Vol-

Volume: ######

Read /

 

ume/Mass

(gal(US)); ######

Write

 

Advisory Limit

(gal(Uk)); ######

 

 

 

(Liters); Mass: ######

 

 

 

(lb), ###### (kg)

 

 

 

 

 

0x264

Flow meter

###### (hours)

Read /

 

Time Advisory

 

Write

 

Limit

 

 

 

 

 

 

0x266

Flow meter

Volume: ######

Read /

 

Volume/Mass

(gal(US)); ######

Write

 

Advisory Limit

(gal(Uk)); ######

 

 

 

(Liters); Mass: ######

 

 

 

(lb), ###### (kg)

 

 

 

 

 

0x268

Supply Time

###### (hours)

Read /

 

Advisory Limit

 

Write

 

 

 

 

0x26A

Supply Vol-

Volume: ######

Read /

 

ume/Mass

(gal(US)); ######

Write

 

Advisory Limit

(gal(Uk)); ######

 

 

 

(Liters); Mass: ######

 

 

 

(lb), ###### (kg)

 

 

 

 

 

0x26C

V/P Time Advi-

###### (hours)

Read /

 

sory Limit

 

Write

 

 

 

 

3A2098H

133

Page 133
Image 133
Graco important safety instructions 3A2098H 133