Installation

Install Control Center

NOTE: This section applies to both the primary control center and the expansion Swirl enclosures.

Mount

Ensure the following criteria are met before mounting the PCF control center:

Select a location for the control center that allows adequate space for installation, service, and use of the equipment.

For best viewing, the ADM should be 60-64 in.

(152-163 cm) from the floor.

Ensure there is sufficient clearance around the con- trol unit to run cables to other components.

Ensure there is safe and easy access to an appro- priate electrical power source. The National Electric Code requires 3 ft (0.91 m) of open space in front of the control center.

Ensure there is easy access to the power switch.

Ensure the mounting surface can support the weight of the control center and the cables attached to it.

Secure the control center with appropriate size bolts through the 0.27 in. (7 mm) diameter holes in the mount- ing tabs. See the following mounting dimensions.

Table 2: Control Center Assembly Measurement

A

10.50 in. (267 mm)

B

5.75 in. (146 mm)

 

 

C

22.00 in. (559 mm)

 

 

D

21.25 in. (540 mm)

 

 

A

B

CD

FIG. 12: Control Center Dimensions