Models

Models

Check the identification (ID) plate for the 6-digit part number of the fluid metering system. Use the following matrix to define the construction of the system, based on the six digits. For example, Part PF1110 represents a PCF fluid

metering system (PF), a two style system (1), a fluid plate with a cartridge regulator and no meter (1), a DeviceNetuser interface (1) with a 100-240 Vac power supply (0).

NOTE: To order replacement parts, see Parts section in this manual. The digits in the matrix do not correspond to the Ref. Nos. in the Parts drawings and lists.

PF

 

1

 

1

 

 

1

 

0

 

 

 

 

 

 

 

 

 

First and

 

Third Digit

 

Fourth Digit

 

Fifth Digit

 

Sixth Digit

 

 

 

 

 

 

 

 

 

Second Digits

 

Style/Size

 

Fluid Plate

 

User Interface

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

Description

 

Regulator

Meter

 

Description

 

Description

PF

1

2 Styles

1

Cartridge

None

0

Discrete

0

100 - 240 Vac

(Precision

 

 

 

 

 

 

 

 

 

2

16 Styles

2

Mastic

None

1

DeviceNet

1

24 Vdc

Continuous

Flow)

3

256 Styles

3

Cartridge

High

2

EtherNet/IP

2

100 - 240 Vac with

 

 

 

 

 

Resolution

 

 

 

Integrated Swirl

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Mastic

High

3

PROFIBUS

3

24 Vdc with

 

 

 

 

 

Resolution

 

 

 

Integrated Swirl

 

 

 

5

Heated

Heated

4

PROFINET

 

 

 

 

 

 

Mastic

Standard

 

 

 

 

 

 

 

 

 

Resolution

 

 

 

 

 

 

 

6

Heated

None

 

 

 

 

 

 

 

 

Mastic

 

 

 

 

 

 

 

 

7

Cartridge

Ultra High

 

 

 

 

 

 

 

 

 

Resolution

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Discrete Gateway systems do not include automation interface cables. The following Graco accessories are avail- able for wiring to the automation system. Installers should follow Appendix B - Discrete Gateway Module (DGM) Connection Details, page 115, for custom wiring.

For single fluid plate systems only: 50 ft (15 m) cable with flying leads (123793)

All systems: Breakout board (123783) and 50 ft (15 m) cable (123792) NOTE: 256 styles option is not available with Discrete Gateway systems.

These fluid metering systems have ETL certification.

NOTE: Fluid metering systems with heated mastic regulators are not ETL certified.

9902471

Certified to CAN/CSA C22.2 No. 61010-1

Conforms to UL 61010-1

C1 This product has been tested to the requirements of CAN/CSA-C22.2 No. 61010-1, second edition, including Amendment 1, or a later version of the same standard incorporating the same level of testing requirements.

4

3A2098H

Page 4
Image 4
Graco 3A2098H important safety instructions Models, Style/Size Fluid Plate, Voltage, Description Regulator