Graco 3A2098H important safety instructions Wed, Wsd, WSD5

Models: 3A2098H

1 142
Download 142 pages 28.28 Kb
Page 70
Image 70

Errors

Event

Gateway

 

Event

 

 

 

 

Code

Error No.

Event Name

Description

Event Type

 

Cause

Solution

 

 

 

 

 

 

 

 

 

 

 

Fluid Plate Events and Errors

 

 

WED_

55

V/P Error

Voltage to Pressure

Alarm

 

Problem detected with

Verify outlet pressure

 

 

 

Transducer error

 

 

V/P

transducer is installed

 

 

 

 

 

 

 

and/or connected cor-

 

 

 

 

 

 

 

rectly

 

 

 

 

 

 

 

Replace if necessary

 

 

 

 

 

 

 

 

WJ1_

56

Dispense Valve 1

Dispense valve 1 error

Alarm

 

Problem detected with

Verify dispense valve 1

 

 

Error

 

 

 

dispense valve 1

is installed and/or con-

 

 

 

 

 

 

 

nected correctly

 

 

 

 

 

 

 

Replace if necessary

 

 

 

 

 

 

 

 

WJ2_

57

Dispense Valve 2

Dispense valve 2 error

Alarm

 

Problem detected with

Verify dispense valve 2

 

 

Error

 

 

 

dispense valve 2

is installed and/or con-

 

 

 

 

 

 

 

nected correctly

 

 

 

 

 

 

 

Replace if necessary

 

 

 

 

 

 

 

 

WJ3_

58

Dispense Valve 3

Dispense valve 3 error

Alarm

 

Problem detected with

Verify dispense valve 3

 

 

Error

 

 

 

dispense valve 3

is installed and/or con-

 

 

 

 

 

 

 

nected correctly

 

 

 

 

 

 

 

Replace if necessary

 

 

 

 

 

 

 

 

WJ4_

59

Dispense Valve 4

Dispense valve 4 error

Alarm

 

Problem detected with

Verify dispense valve 4

 

 

Error

 

 

 

dispense valve 4

is installed and/or con-

 

 

 

 

 

 

 

nected correctly

 

 

 

 

 

 

 

Replace if necessary

 

 

 

 

 

 

 

 

WSD_

60

Incompatible

Incompatible settings

Alarm

 

Attempted to dis-

Check settings shown

 

 

Valve Settings

for multiple valve opera-

 

 

pense simultaneously

on Fluid Plate x,

 

 

 

tion; attempted to dis-

 

 

from multiple valves

screen 2 (Mode Set-

 

 

 

pense

 

 

on the same fluid plate

tings)

 

 

 

 

 

 

with different pressure

Verify automation pro-

 

 

 

 

 

 

settings

 

 

 

 

 

 

 

gramming

WSD5

60

Incompatible

Incompatible settings

Alarm

 

Attempted to dis-

In the Discrete Gate-

 

 

Valve Settings

for multiple valve opera-

 

 

pense simultaneously

way screens, change

 

 

 

tion; attempted to dis-

 

 

from multiple valves

the settings of the

 

 

 

pense

 

 

on the same fluid plate

simultaneously dis-

 

 

 

 

 

 

with different pressure

pensing valves to the

 

 

 

 

 

 

settings

same pressure

 

 

 

 

 

 

 

Verify automation pro-

 

 

 

 

 

 

 

gramming

 

 

 

 

 

 

 

 

F7D_

61

Closed Valve

System reading flow

Alarm

 

Dispense hose leak

Check hose; replace if

 

 

Flow

meter pulses with

 

 

 

needed

 

 

 

valve(s) closed

 

 

 

 

 

 

 

 

 

Flow meter providing

Replace flow meter

 

 

 

 

 

 

 

 

 

 

 

 

false pulses

sensor or calibrate

 

 

 

 

 

 

 

meter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dispense valve not

Repair dispense valve

 

 

 

 

 

 

operating correctly

 

 

 

 

 

 

 

 

 

70

3A2098H

Page 70