Technical Data

Technical Data

*Minimum Flow Rates . . . . . . . . . . . . . . . . . . . . . . . . . . .

*Maximum Flow Rates . . . . . . . . . . . . . . . . . . . . . . . . . . .

Maximum Fluid Working Pressure

feed pressure to fluid plate (cartridge regulator) . . . .

feed pressure to fluid plate (mastic regulator) . . . . . .

at regulator outlet. . . . . . . . . . . . . . . . . . . . . . . . . . . .

at regulator outlet with electric heat components . . .

Minimum Fluid Working Pressure (at regulator outlet). . .

Air Supply Pressure Range . . . . . . . . . . . . . . . . . . . . . . .

Fluid Filtration Required . . . . . . . . . . . . . . . . . . . . . . . . . .

*Viscosity Range of Fluids . . . . . . . . . . . . . . . . . . . . . . . .

*Minimum Dispensed Shot Size. . . . . . . . . . . . . . . . . . . .

Wetted Parts (meters and fluid plates). . . . . . . . . . . . . . .

Power Requirements

100-240 Vac . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

24 Vdc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Power Supply Voltage Range . . . . . . . . . . . . . . . . . . . . .

Operating Temperature Range

control center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

heated fluid plate . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ambient fluid plate . . . . . . . . . . . . . . . . . . . . . . . . . . .

Operating Humidity Range. . . . . . . . . . . . . . . . . . . . . . . .

25 cc/minute with high-resolution (ambient) helical flow meter

50 cc/minute with heated helical flow meter

7500 cc/minute with high-resolution (ambient) helical flow meter

22,500 cc/minute with heated helical flow meter

37,500 cc/minute with separate flow meter

6000 psi (41 MPa, 414 bar)

5000 psi (35 MPa, 345 bar)

4500 psi (31 MPa, 310 bar)

3500 psi (24 MPa, 241 bar)

100 psi (0.7 MPa, 7.0 bar)

60-120 psi (0.4 - 0.8 MPa, 4.1- 8.3 bar) - 10 Micron filtra- tion required

30 mesh (500 micron) minimum

10,000 to 1,000,000 cps with helical flow meter

3 cc with high-resolution (ambient) helical flow meter 6 cc with heated helical flow meter

303, 304, 321, 17- 4 stainless steel; tungsten carbide, PTFE, steel, fluoroelastomer

full load-1.4A, fuse rating-2.5A full load-4A, fuse rating-4A

100-240 Vac, 50-60 Hz, single phase

40°F (4°C) - 120°F (49°C) 40°F (4°C) - 400°F (204°C) 40°F (4°C) - 120°F (49°C) 0 - 90% non-condensing

*Flow rates and viscosities are general estimates. Flow rates drop as viscosity increases. Fluids are expected to shear under pressure. New applications or fluids should always be tested to determine proper line sizes and equip- ment selections. See your Graco authorized distributor for other capabilities.

Control Center Assembly Technical Data

 

100 - 240 Vac Assemblies

24 Vdc Assembly

 

 

 

Voltage

100-240 Vac

24 Vdc

 

 

 

Phase

1

---

 

 

 

Frequency

50-60 Hz

---

 

 

 

Full Load Current

1.4 A

4.0 A

 

 

 

Fuse Rating

250 Vac, 2.5A T

125 Vac, 4A F

 

 

 