Installation

Install Cable Assemblies

NOTE: To prevent system errors, only connect cables with the power off.

NOTE: See FIG. 17 on page 29.

1.For systems with more than one swirl dispenser: Use a CAN cable to connect the control center to one swirl expansion enclosure. Use additional CAN cables to connect any remaining expansion swirl enclosures together in sequence.

2.For systems with one or more swirl dispensers, use motor cable to connect each swirl dispenser to an expansion swirl enclosure or to the control center.

3.Connect a CAN cable from the control center to one fluid plate assembly.

4.For multiple fluid plate systems, use CAN cables to connect each fluid plate to one other fluid plate Repeat until all fluid plates are connected to one other fluid plate.

NOTE: Use the connections on the CAN splitter on the left side of each fluid plate to connect the fluid plates together. There will be a CAN splitter on all but one fluid plate.

NOTE: The control center, expansion swirl enclosures, and fluid plates may be connected in any order as long as each is connected to another system component with a CAN cable. See the example shown in FIG. 17 on page 29.

5.Use the automation interface cable (not provided) to connect the Gateway module to the automation controller.

28

3A2098H

Page 28
Image 28
Graco 3A2098H important safety instructions Install Cable Assemblies