Installation

Install Command Cable Kit 24B694

Follow this procedure if using the command cable kit.

1.Install bulkhead fitting (included in the kit) into the empty hole on the fluid plate. See FIG. 16 on page 25.

2.Connect one end of the extension cable (included in the kit) to connection 5 on the FCM and the other end of the cable to the bulkhead fitting.

3.Connect command cable to bulkhead fitting and wire to automation controller per the following pinout table.

 

 

Function

 

 

 

 

FCM

Command

Dispense Trigger Source:

 

Port

Cable Wire

‘Command Cable’ or

Dispense Trigger Source:

Pin #

Color

‘Combined’

‘Command Cable 3x’

 

 

 

 

1

White

Command voltage (0-10 Vdc)

Command voltage (0-10 Vdc)

 

 

 

 

2

Brown

No connection

Valve 3 dispense trigger (*sourcing

 

 

 

input)

 

 

 

 

3

Green

Dispense trigger (*sourcing input)

Valve 1 dispense trigger (*sourcing

 

 

 

input)

 

 

 

 

4

Yellow

No connection

Valve 2 dispense trigger (*sourcing

 

 

 

input)

 

 

 

 

5

Gray

Dispense trigger ground

Dispense trigger ground

 

 

 

 

6

Pink

No connection

No connection

 

 

 

 

7

Blue

Command signal ground

Command signal ground

 

 

 

 

8

Red

No connection

No connection

 

 

 

 

NOTE: Command cable inputs are not isolated from

PCF 24 Vdc power.

*To turn on the dispense trigger, connect the dis- pense trigger pin to the dispense trigger ground pin (pin 5).

26

3A2098H

Page 26
Image 26
Graco 3A2098H important safety instructions Install Command Cable Kit 24B694, Fcm