Appendix C - Communications Gateway Module (CGM) Connection Details

Units Definitions

Unit s String

Definition

 

 

 

 

 

 

 

 

 

Command Value Source Enu-

0

- Display, 1 - Command Cable, 2 - Gateway

 

 

meration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dispense Control 1 Bitfield

Bit

Function

3

Valve 2 On

6

Error Reset

 

0

............

Style Strobe

4

Valve 3 On

7

Remote Start/Purge

 

1

............

Dispense Complete

5

Valve 4 On

 

 

 

2

............

Valve 1 On

 

 

 

 

 

 

 

 

Dispense Control 2 Bitfield

Bit 14 - Error Reset, Bit 15 - Remote Start

 

 

 

 

 

Dispense Trigger Source Enu-

0

- Command Cable, 1 - Gateway, 2 - Combined, 3 - Command Cable 3x

meration

 

 

 

 

 

 

 

 

 

 

 

 

 

Error Type Enumeration 1

0

- None, 1 - Alarm, 2 - Deviation

 

 

 

 

 

 

 

 

 

 

Error Type Enumeration 2

1

- Alarm, 2 - Deviation

 

 

 

 

 

 

Fault Error Code

A 32-bit string in the format of 0xDDCCBBAA where 0xAA represents the most significant char-

 

acter in the string and 0xDD represents the least significant character in the string.

 

 

 

 

 

 

 

Flow Meter Type Enumeration

1

- Volume, 2 - Mass

 

 

 

 

 

 

 

 

 

 

 

Fluid Plate Status 0 Bitfield

Bit

Function

3

Dispense In Process

7

Purge in Process/Remote

 

0

............

Dispenser Ready

4

Dispensed Volume OK

Start in Process

 

1

............

Dispense No Alarm

5

---

 

 

 

2

............

Dispense No Error

6

Dispenser Purge Request

 

 

 

 

 

 

 

 

 

Fluid Plate Status Bitfield

Bit

Function

11

Alarm Active

24

Valve 3 Swirl Installed

 

0-2

Operation Mode (see Valve

12

Deviation Active

25

Valve 4 Swirl Installed

 

Mode Enumeration)

13

Advisory Active

26

Valve 1 Swirl Active

 

3

............

Precharge Active

14

Dispensing Disabled

27

Valve 2 Swirl Active

 

4

............

Valve 1 State

15

Fluid Plate Enabled

28

Valve 3 Swirl Active

 

5

............

Valve 2 State

16

Flowmeter Enabled

29

Valve 4 Swirl Active

 

6

............

Valve 3 State

17

Inlet Sensor Enabled

30

Fault Reset

 

7

............

Valve 4 State

18

Heated Plate

31

Remote Start/Purge

 

8

............

Ready to Dispense

19

Integrator Enabled

 

 

 

9

............

In Job Cycle

22

Valve 1 Swirl Installed

 

 

 

10

Job Cycle Complete

23

Valve 2 Swirl Installed

 

 

 

 

 

 

 

 

 

Job End Mode Enumeration

0

- Timer, 1 - Gateway

 

 

 

 

 

 

 

 

 

 

 

Maintenance Units Enumeration

0

- Volume, 1 - Mass, 2 - Time

 

 

 

 

 

 

 

 

 

 

 

Mass Units Enumeration

0

- lb, 1 - kg

 

 

 

 

 

 

 

 

Precharge Settings Type

A 32 bit value in the format of 0xDDCCBBA:

 

 

 

0xA........Precharge mode enumeration: 0 - Display, 1 - Gateway, 2 - Valve 1

 

0xBBB...

Precharge valve opening duration (ms)

 

 

 

0xCC

Precharge scale - valve closed (%)

 

 

 

0xDD

Precharge scale - valve opening (%)

 

 

 

 

 

 

 

 

 

Pressure Units Enumeration

0

- psi, 1 - bar, 2 - MPa

 

 

 

 

 

 

 

 

 

 

 

Rate Units Enumeration

0

- x/min, 1 - x/sec

 

 

 

 

 

 

 

 

 

sint32

A 32 bit positive or negative value

 

 

 

 

 

 

 

 

 

 

Speed Source Enumeration

0

- Display, 1 - Gateway

 

 

 

 

 

 

STR_X_Y

A 32 bit value where X signifies which character in the string that the most significant byte rep-

 

resents and Y signifies which character in the string that the least significant byte represents.

 

 

 

 

 

 

 

Swirl Control Enumeration

0

- Swirl Enable

 

 

 

 

 

 

 

 

 

Swirl Enumeration

0

- None, 1 - Swirl 1, 2 - Swirl 2, 3 - Swirl 3, 4 - Swirl 4

 

 

 

 

 

 

 

Swirl Status Bitfield 1

0

- Swirl Active, 1 - Swirl Ready, 2 - Swirl Enabled

 

 

 

 

Tolerances Type

A 32 bit value in the format of 0x0000BBAA where 0xAA represents the low tolerance (%) and

 

0xBB represents the high tolerance (%). A value of 0 means that tolerance is disabled.

 

 

 

 

 

Valve Mode Enumeration

0

- Pressure, 1 - Bead, 2 - Shot, 3 - Full Open

 

 

 

 

 

 

 

 

uint12

A 12 bit positive value

 

 

 

 

 

 

 

 

 

 

uint32

A 32 bit positive value

 

 

 

 

 

 

Version

A 32 bit value in the format of 0x00CCBBAA where 0xAA represents the major version, 0xBB

 

represents the minor version and 0xCC represents the build version.

 

 

 

 

 

 

 

Volume Units Enumeration

0

- gal(US), 1 - gal(UK), 2 - Liters

 

 

 

 

 

 

 

 

 

 

 

3A2098H

137

Page 137
Image 137
Graco 3A2098H important safety instructions Units Definitions, Unit s String Definition, Strxy