Installation

Installation

Before Installation

Have all system and component documentation available during installation.

See component manuals for specific data on compo- nent requirements. Data presented here applies to the PCF assemblies only.

Be sure all accessories are adequately sized and pressure-rated to meet system requirements.

Use the PCF control center only with the PCF fluid plate assembly.

Overview

The basic steps to install a PCF system are shown below. See the separate component manuals for detailed information.

To avoid injury and damage to equipment, use at least two people to lift, move, or disconnect the sys- tem. The system is too heavy for one person to lift or move.

Installation Steps

1.Mount control center, page 22.

2.For systems with multiple swirl dispensers, mount expansion Swirl enclosures, page 22.

3.Connect and ground control center and expansion Swirl enclosures, page 23.

4.Mount each fluid plate assembly, page 24.

5.Ground each fluid plate assembly, page 27.

6.Check ground continuity.

7.Connect fluid lines between each fluid plate and applicator. Connect fluid supply line and air supply to module. See page 27.

8.Plumb air filter assembly near air supply drop site that will be used for fluid plate assembly.

9.For systems with swirl dispensers, install each swirl dispenser onto outlet of a dispense valve.

10.Connect other fluid and air lines to additional system components as instructed in their manuals.

11.Install fluid plate, swirl, and gateway cable assem- blies, page 28.

12.Install Gateway interface, page 30.

3A2098H

21

Page 21
Image 21
Graco 3A2098H important safety instructions Before Installation, Overview, Installation Steps