Control Center Assembly

Prepare Control Center for Repair

1.Power off the display.

2.Disconnect main power to the control center assem- bly.

3.Remove the control center assembly front cover (20).

Repair

Replace Gateway Module Base

1.Prepare Control Center for Repair, page 87.

2.Remove the Gateway module (5); follow Replace Gateway Module. (Leave automation communica- tions cable (AE) attached to Gateway module.)

3.Disconnect the CAN cable (19) and power supply cable (6) from the base (3).

4.Remove the four screws (16) and grounding screw (12) from the base and replace it with a new base.

Replace Gateway Module

1.Prepare Control Center for Repair, page 87.

2.Remove the automation communications cable (AE).

3.Remove the two screws holding the Gateway mod- ule (5) to the base (3), and remove the module.

6

3

1

19

3

5

FIG. 60

4.Attach a new Gateway module to the base using two screws.

5.Reconnect the automation interface cable.

6.Upgrade software, page 77, then upgrade fieldbus map, page 78.

12

5

16

4

FIG. 61

5.Secure the new base to rear cover (1) using the five screws.

6.Reattach Gateway module; follow Replace Gate- way Module.

3A2098H

87

Page 87
Image 87
Graco 3A2098H Control Center Assembly, Prepare Control Center for Repair, Replace Gateway Module