Appendix C - Communications Gateway Module (CGM) Connection Details

Command Interface Timing Diagram

 

Write Command

Read Command

Automation Outputs (PCF Inputs)

 

 

Command Bits 256-275

Bits Set

Bits Set

Value Bits 288-319

Bits Set

 

Write Bit 321

 

 

Read Bit 320

 

 

Automation Inputs (PCF Outputs)

 

 

Value Bits 128-159

Bits Set

Bits Set

Command Active Bit 160

 

 

Command Success Bit 161

 

 

Command Failure Bit 162

 

 

Command Value Coerced Bit 163

 

 

FIG. 73: CGM Command Interface Timing Diagram

Command Interface Write Operation

1.Set Command Identification Bits and Fluid Plate/Swirl Identification Bits to the desired values.

2.Set Value Bits (Output) with the value that is desired to be written.

3.Set Write Bit.

4.Wait for the Command Active Bit to become set. This indicates that an operation is in process.

5.Wait for the Command Success Bit, Command Fail- ure Bit, or Command Value Coerced Bit to become set.

NOTE: The Value Bits (Input) now contain the value that was actually written.

6.Clear the Write Bit to end the write command opera- tion.

Command Interface Read Operation

4.Wait for the Command Success Bit or Command Failure Bit to become set.

NOTE: If Command Success Bit has been set, valid data will be present within the Value Bits (Input).

5.Clear the Read Bit to end the read command opera- tion.

Fluid Plate/Swirl Identification Commands

Output Bits 268-275

Description

 

 

0xB0

Fluid Plate 1

 

 

0xB1

Fluid Plate 2

 

 

0xB2

Fluid Plate 3

 

 

0xB3

Fluid Plate 4

 

 

0xE1

Swirl 1

 

 

0xE2

Swirl 2

 

 

0xE3

Swirl 3

 

 

0xE4

Swirl 4

 

 

Fluid Plate Commands

1.Set Command Identification Bits and Fluid Plate/Swirl Identification Bits to the desired values.

2.Set Read Bit.

3.Wait for the Command Active Bit to become set. This indicates that an operation is in process.

Output

 

Units

 

Bits

 

*See Units

Read or

256-267

Description

Definitions, page 137

Write

 

 

 

 

0x004

Software Part

STR_3_0

Read Only

 

Number

 

 

 

 

 

 

0x005

Software Part

STR_7_4

Read Only

 

Number

 

 

 

 

 

 

0x006

Software Part

STR_11_8

Read Only

 

Number

 

 

 

 

 

 

132

3A2098H

Page 132
Image 132