Appendix C - Communications Gateway Module (CGM) Connection Details

CGM I/O Data Map

See Appendix D - I/O Signal Descriptions on page 138.

Automation Inputs (signals from PCF)

 

Input

 

 

Byte

Bit

Description

Zone

 

 

 

 

 

I00

Dispenser (Fluid Plate) Ready

 

 

I01

Dispenser (Fluid Plate) No Alarm

 

 

I02

Dispense No Error

 

 

I03

Dispense in Process

 

 

 

 

Fluid

0

I04

Dispense Volume OK

 

 

Plate 1

I05

---

 

 

I06

Dispenser (Fluid Plate) Purge

 

 

 

Request

 

 

 

 

 

 

I07

Dispenser (Fluid Plate) Remote

 

 

 

Start / Purge In Process

 

 

 

 

 

 

I08

Pressure Units - Bit 0

 

 

I09

Pressure Units - Bit 1

 

 

I10

---

 

 

 

 

Fluid

1

I11

---

I12

---

Plate 1

 

 

I13

---

 

 

I14

---

 

 

I15

---

 

 

I16

---

 

 

I17

---

 

 

I18

---

 

 

 

 

Fluid

2

I19

---

I20

---

Plate 1

 

 

I21

---

 

 

I22

---

 

 

I23

---

 

 

I24

Error - 1

 

 

I25

Error - 2

 

 

I26

Error - 4

 

 

 

 

Fluid

3

I27

Error - 8

I28

Error - 16

Plate 1

 

 

I29

Error - 32

 

 

I30

Error - 64

 

 

I31

Error - 128

 

 

I32

Dispenser (Fluid Plate) Ready

 

 

I33

Dispenser (Fluid Plate) No Alarm

 

 

I34

Dispense No Error

 

 

I35

Dispense in Process

 

 

 

 

Fluid

4

I36

Dispense Volume OK

 

 

Plate 2

I37

---

 

 

I38

Dispenser (Fluid Plate) Purge

 

 

 

Request

 

 

 

 

 

 

I39

Dispenser (Fluid Plate) Remote

 

 

 

Start / Purge In Process

 

 

 

 

 

 

Input

 

 

Byte

Bit

Description

Zone

 

 

 

 

 

I40

Pressure Units - Bit 0

 

 

I41

Pressure Units - Bit 1

 

 

I42

---

 

 

 

 

Fluid

5

I43

---

I44

---

Plate 2

 

 

I45

---

 

 

I46

---

 

 

I47

---

 

 

I48

---

 

 

I49

---

 

 

I50

---

 

 

 

 

Fluid

6

I51

---

I52

---

Plate 2

 

 

I53

---

 

 

I54

---

 

 

I55

---

 

 

I56

Error - 1

 

 

I57

Error - 2

 

 

I58

Error - 4

 

 

 

 

Fluid

7

I59

Error - 8

I60

Error - 16

Plate 2

 

 

I61

Error - 32

 

 

I62

Error - 64

 

 

I63

Error - 128

 

 

I64

Dispenser (Fluid Plate) Ready

 

 

I65

Dispenser (Fluid Plate) No Alarm

 

 

I66

Dispense No Error

 

 

I67

Dispense in Process

 

 

 

 

Fluid

8

I68

Dispense Volume OK

 

 

Plate 3

I69

---

 

 

I70

Dispenser (Fluid Plate) Purge

 

 

 

Request

 

 

 

 

 

 

I71

Dispenser (Fluid Plate) Remote

 

 

 

Start / Purge In Process

 

 

 

 

 

 

I72

Pressure Units - Bit 0

 

 

I73

Pressure Units - Bit 1

 

 

I74

---

 

 

 

 

Fluid

9

I75

---

I76

---

Plate 3

 

 

I77

---

 

 

I78

---

 

 

I79

---

 

 

I80

---

 

 

I81

---

 

 

I82

---

 

 

 

 

Fluid

10

I83

---

I84

---

Plate 3

 

 

I85

---

 

 

I86

---

 

 

I87

---

 

3A2098H

125

Page 125
Image 125
Graco 3A2098H CGM I/O Data Map, Automation Inputs signals from PCF, See Appendix D I/O Signal Descriptions on