Appendix C - Communications Gateway Module (CGM) Connection Details

 

Input

 

 

Byte

Bit

Description

Zone

 

 

 

 

 

I88

Error - 1

 

 

I89

Error - 2

 

 

I90

Error - 4

 

 

 

 

Fluid

11

I91

Error - 8

I92

Error - 16

Plate 3

 

 

I93

Error - 32

 

 

I94

Error - 64

 

 

I95

Error - 128

 

 

I96

Dispenser (Fluid Plate) Ready

 

 

I97

Dispenser (Fluid Plate) No Alarm

 

 

I98

Dispense No Error

 

 

I99

Dispense in Process

 

 

 

 

Fluid

12

I100

Dispense Volume OK

I101

---

Plate 4

 

 

I102

Dispenser (Fluid Plate) Purge

 

 

 

Request

 

 

 

 

 

 

I103

Dispenser (Fluid Plate) Remote

 

 

 

Start / Purge In Process

 

 

 

 

 

 

I104

Pressure Units - Bit 0

 

 

I105

Pressure Units - Bit 1

 

 

I106

---

 

 

 

 

Fluid

13

I107

---

I108

---

Plate 4

 

 

I109

---

 

 

I110

---

 

 

I111

---

 

 

I112

---

 

 

I113

---

 

 

I114

---

 

 

 

 

Fluid

14

I115

---

I116

---

Plate 4

 

 

I117

---

 

 

I118

---

 

 

I119

---

 

 

I120

Error - 1

 

 

I121

Error - 2

 

 

I122

Error - 4

 

 

 

 

Fluid

15

I123

Error - 8

I124

Error - 16

Plate 4

 

 

I125

Error - 32

 

 

I126

Error - 64

 

 

I127

Error - 128

 

 

I128

Command Interface - Value - Bit 0

 

 

 

See CGM Command Interface on

 

 

 

page 131 for command interface

 

 

 

details.

 

 

 

 

All Fluid

 

I129

Command Interface - Value - Bit 1

16

 

 

Plates/Swi

I130

Command Interface - Value - Bit 2

 

 

 

rls

 

I131

Command Interface - Value - Bit 3

 

I132

Command Interface - Value - Bit 4

 

 

I133

Command Interface - Value - Bit 5

 

 

I134

Command Interface - Value - Bit 6

 

 

I135

Command Interface - Value - Bit 7

 

 

Input

 

 

Byte

Bit

Description

Zone

 

 

 

 

 

I136

Command Interface - Value - Bit 8

 

 

I137

Command Interface - Value - Bit 9

 

 

I138

Command Interface - Value - Bit 10

All Fluid

 

I139

Command Interface - Value - Bit 11

17

Plates/Swi

I140

Command Interface - Value - Bit 12

 

rls

 

I141

Command Interface - Value - Bit 13

 

 

 

I142

Command Interface - Value - Bit 14

 

 

I143

Command Interface - Value - Bit 15

 

 

I144

Command Interface - Value - Bit 16

 

 

I145

Command Interface - Value - Bit 17

 

 

I146

Command Interface - Value - Bit 18

All Fluid

 

I147

Command Interface - Value - Bit 19

18

Plates/Swi

I148

Command Interface - Value - Bit 20

 

 

 

rls

 

I149

Command Interface - Value - Bit 21

 

 

 

I150

Command Interface - Value - Bit 22

 

 

I151

Command Interface - Value - Bit 23

 

 

I152

Command Interface - Value - Bit 24

 

 

I153

Command Interface - Value - Bit 25

 

 

I154

Command Interface - Value - Bit 26

All Fluid

 

I155

Command Interface - Value - Bit 27

19

Plates/Swi

I156

Command Interface - Value - Bit 28

 

rls

 

I157

Command Interface - Value - Bit 29

 

 

 

I158

Command Interface - Value - Bit 30

 

 

I159

Command Interface - Value - Bit 31

 

 

I160

Command Interface Status - Com-

 

 

 

mand Active

 

 

 

 

 

 

I161

Command Interface Status - Com-

 

 

 

mand Success

 

 

 

 

 

 

I162

Command Interface Status - Com-

All Fluid

 

 

mand Failure

20

 

Plates/Swi

 

 

I163

Command Interface Status - Value

 

 

Coerced

rls

 

 

 

 

 

 

 

 

I164

---

 

 

I165

---

 

 

I166

---

 

 

I167

---

 

21-

I168-

---

---

25

I207

 

 

126

3A2098H

Page 126
Image 126
Graco 3A2098H important safety instructions See CGM Command Interface on